![Manitowoc MLC650 Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/manitowoc/mlc650/mlc650_service-maintenance-manual_701260091.webp)
Reference
Only
Manitowoc
Published 09-09-16, Control # 229-09
3-29
MLC650 SERVICE/MAINTENANCE MANUAL
ELECTRICAL SYSTEM
3
PD-26
No Connection
PD-27
KL15
Control Module Ignition Power (from relay K5)
0 V
DC
Open, 24 V
DC
Closed
PD-28
ID9
Upper Boom Point Confirm
0 V
DC
Not Installed, 24 V
DC
Installed
PD-29
GND
Ground (from load center)
0 V
DC
PD-30
CAN1_L
CAN Bus D—Low
Not Applicable
PD-31
CAN1_H
CAN Bus D—High
Not Applicable
PD-32
No Connection
PD-33
No Connection
PD-34
No Connection
PD-35
No Connection
PD-36
No Connection
PD-37
IACV14
Wind Speed Sensor
0 to 20 mA
PD-38
IACV15
Upper Boom Point Load Pin
0 V
DC
Open, 24 V
DC
Closed
PD-39
IACV16
Not Used—For Possible Future Expansion
0 V
DC
PD-40
No Connection
PD-41
No Connection
PD-42
No Connection
Pin
I/O Network
Function
Voltages