Table 3-17. IOLC32 Test Voltages
Pin
I/O Network
Function
Voltages
PC1-1
GND
Ground (from ground stud on rotating bed)
0 V
DC
PC1-2
KL15
Control Module Ignition Power (from engine run switch)
0 V
DC
Open, 24 V
DC
Closed
PC1-3
ID01
Hydraulic Charge Filter Alarm Pressure Switch
0 V
DC
Open, 24 V
DC
Closed
PC1-4
No Connection
PC1-5
OPH6A18
Drum 3/2 Pump 2
0 V
DC
Open, 24 V
DC
Closed
PC1-6
OPH6A19
Drum 3/2 Pump 2
0 V
DC
Open, 24 V
DC
Closed
PC1-7
OPH6A20
Right Travel/Drum 2 Pump 4
0 V
DC
Open, 24 V
DC
Closed
PC1-8
OPH6A21
Right Travel/Drum 2 Pump 4
0 V
DC
Open, 24 V
DC
Closed
PC1-9
IMID1
Module Identifier Input (from ground stud on rotating bed)
0 V
DC
PC1-10
CAN1_H
CAN Bus C—High
Not Applicable
PC1-11
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC1-12
+U
E
Control Module Battery Power
24 V
DC
PC1-13
No Connection
PC1-14
No Connection
PC1-15
No Connection
PC1-16
ID06
VPC Tray Max In Switch
0 V
DC
Open, 24 V
DC
Closed
PC1-17
IDF15
Not Used—For Possible Future Expansion
0 V
DC
PC1-18
No Connection
PC1-19
CAN1_L
CAN Bus C—Low
Not Applicable
PC1-20
+U
B
Supply Power for Control Module Outputs
24 V
DC
PC1-21
ID07
Hydraulic Vacuum Switch
0 V
DC
Open, 24 V
DC
Closed
PC1-22
ID08
Drum 4 Pawl Limit Switch
0 V
DC
Open, 24 V
DC
Closed
PC1-23
ID09
Active Fixed Mast Stop System Connected
0 V
DC
Not Installed, 24 V
DC
Installed
PC1-24
ID10
Not Used—For Possible Future Expansion
0 V
DC
PC1-25
ID11
Not Used—For Possible Future Expansion
0 V
DC
PC1-26
IDF16
Not Used—For Possible Future Expansion
0 V
DC
PC1-27
IACV17
Hydraulic Fluid Temperature Sensor
0.5 to 4.5 V
DC
PC1-28
IMID4
Module Identifier Input (from ground stud on rotating bed)
0 V
DC
PC1-29
IMID3
Module Identifier Input (from ground stud on rotating bed)
0 V
DC
PC2-1
ID12
Not Used—For Possible Future Expansion
0 V
DC
PC2-2
ID13
Not Used—For Possible Future Expansion
0 V
DC
PC2-3
No Connection
PC2-4
IACV18
Hydraulic Fluid Level Sensor
1 V
DC
Full, 9 V
DC
Empty
PC2-5
ODH3A02
Drum 4 Pawls Out Solenoid
0 V
DC
Off, 24 V
DC
On
Содержание MLC650
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc MLC650 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 375: ...R e f e r e n c e O n l y ...
Страница 376: ...R e f e r e n c e O n l y ...