Reference
Only
ACCESSORIES
MLC650 SERVICE/MAINTENANCE MANUAL
10-60
Published 09-09-16, Control # 229-09
VPC-MAX Beam Pin Pullers
The VPC-MAX frame assembly auxiliary member attaches
to the VPC-MAX beam assembly using four hydraulically
actuated pins. The pin cylinders are controlled by the setup
remote.
See
for an illustration of the VPC-MAX beam
pin pullers shown retracted.
for an illustration of the frame assembly
auxiliary member connected to the VPC-MAX beam
assembly.
See
for the hydraulic schematic of the VPC-
MAX beam pin pullers circuit.
See
for the electrical schematic of the VPC-
MAX beam pin pullers circuit.
Setup Remote Overview
NOTE:
The setup remote is covered in Section 4 of the
Operator Manual.
The setup remote control communicates with the CCM-10
control module using the controller area network bus (CAN
Bus). The crane control modules use the CAN Bus to
communicate with each other.
Neutral Position Using Setup Remote
for the following.
When the setup remote is not sending a command, the
upper and lower pin puller valve spools (3 and 4) are held in
the neutral position by the return springs. When in neutral,
the valve spools connect both the piston end and rod end of
the upper and lower pin puller cylinders (1 and 2) to the tank.
Extend Pin Puller Cylinders Using Setup Remote
for the following.
When a command to extend the VPC-MAX beam pin puller
cylinders is initiated on the setup remote, the CCM-10
control module sends the command to the IOLC35 control
module. The IOLC35 control module then sends a 24 V
DC
output voltage to the upper and lower pin puller extend
solenoids (5 and 6), energizing the solenoids.
The energized solenoids route hydraulic fluid from the
accessory pump to the piston end of the upper and lower pin
puller cylinders (1 and 2). At the same time, hydraulic fluid in
the rod end of the cylinders is forced out and back to the
tank. This causes the rods to extend, engaging the pins.
Retract Pin Puller Cylinders Using Setup Remote
for the following.
When a command to retract the VPC-MAX beam pin puller
cylinders is initiated on the setup remote, the CCM-10
control module sends the command to the IOLC35 control
module. The IOLC35 control module then sends a 24 V
DC
output voltage to the upper and lower pin puller retract
solenoids (7 and 8), energizing the solenoids.
The energized solenoids route hydraulic fluid from the
accessory pump to the rod end of the upper and lower pin
puller cylinders (1 and 2). At the same time, hydraulic fluid in
the piston end of the cylinders is forced out and back to the
tank. This causes the rods to retract, disengaging the pins.
Item Description
1
VPC-MAX Beam Pin Puller Cylinder (qty 4)
2
VPC-MAX Beam Assembly
FIGURE 10-47
Содержание MLC650
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc MLC650 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 375: ...R e f e r e n c e O n l y ...
Страница 376: ...R e f e r e n c e O n l y ...