![Manitowoc MLC650 Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/manitowoc/mlc650/mlc650_service-maintenance-manual_701260089.webp)
Reference
Only
Manitowoc
Published 09-09-16, Control # 229-09
3-27
MLC650 SERVICE/MAINTENANCE MANUAL
ELECTRICAL SYSTEM
3
PD-29
GND
Ground (from load center)
0 V
DC
PD-30
CAN1_L
CAN Bus D—Low
Not Applicable
PD-31
CAN1_H
CAN Bus D—High
Not Applicable
PD-32
No Connection
PD-33
No Connection
PD-34
IMID2
Module Identifier Input (ground from load center)
0 V
DC
PD-35
ID7
EUBP Block-Up Limit Switch 1
0 V
DC
Open, 24 V
DC
Closed
PD-36
ID8
EUBP Block-Up Limit Switch 2
0 V
DC
Open, 24 V
DC
Closed
PD-37
IACV14
EUBP Wind Speed Sensor
0 to 20 mA
PD-38
IACV15
Lower Boom Point Load Link
0 V
DC
Open, 24 V
DC
Closed
PD-39
IACV16
Not Used—For Possible Future Expansion
0 V
DC
PD-40
No Connection
PD-41
No Connection
PD-42
ID10
Not Used—For Possible Future Expansion
0 V
DC
Pin
I/O Network
Function
Voltages