ELECTRICAL SYSTEM
3
CIRCUIT BREAKERS, FUSES, AND RELAYS
For past production Tier 3 cranes, the alternator circuit
breaker CB0 (1) is mounted next to the battery box
(
For Tier 4 cranes and current production Tier 3 cranes, the
alternator fuse F0 (2) is mounted on a panel left of the battery
box (
).
The TCU CraneStar fuse F5 (3) is mounted on the battery
disconnect bracket.
All other circuit breakers and fuses are mounted in the
junction box DC load center (
All relays are also mounted in the junction box DC load
center (
Item Description
1
CB0—Alternator 150 A Circuit Breaker (Tier 3—Past Production)
2
F0—Alternator 150 A Fuse (Tier 4 and Tier 3—Current Production)
3
F5—TCU CraneStar 5 A Fuse
FIGURE 3-3