Item
Lube Point
Description
Figure No.
Approved
Lubricant
Approximate
Capacity
Service Interval
Service
Application
Drive Train
(Continued)
4
Fuel Filter
—
—
PERFORM
every
500 hours of service,
or 6 months, which-
ever interval is first
REPLACE fuel filter
5
Transmission and
Torque Converter
E
41.6 L (11 gal)
PERFORM
every
10 hours of service,
or daily, whichever
interval comes first
CHECK fluid level
FILL transmission
sump to FULL on
DIPSTICK
PERFORM
after first
50 hours of service,
and
REPEAT
after
another 50 hours for
a total of 100 hours of
service
DRAIN transmission
sump
REPLACE trans-
mission and torque
converter filter
CLEAN magnetic
drain plug
INSTALL magnetic
plug in drain port
FILL transmission
sump to FULL on
DIPSTICK
Thereafter
PERFORM
DRAIN
procedure, to include
REPLACING
transmission and
torque converter
filter, every 500 hours
of service, or
3 months, whichever
interval comes first
DRAIN transmission
sump
REPLACE filter
FILL transmission
sump to FULL on
DIPSTICK
NOTE 10:
The Fuel Filter is located on the inside right side of the frame adjacent to the engine.
NOTE 11:
Check Transmission Fluid level using the dipstick (6
A
)
that is located on the right side of the carrier, behind the
steps, adjacent to the hydraulic tank. Check fluid level with boom fully retracted and lowered, and all outrigger
cylinders retracted.
NOTE 12
: Level should be checked with engine running at 850 rpm idle and torque converter fluid temp at 65°C to 93°C
(150°F to 200°F). To bring fluid temperature to this range, it is necessary to work the crane or stall the converter.
Содержание Grove GRT8120
Страница 1: ...Operator Manual Grove GRT8120 ...
Страница 4: ...THIS PAGE BLANK ...
Страница 16: ...TABLE OF CONTENTS GRT8120 A 12 THIS PAGE BLANK ...
Страница 24: ...INTRODUCTION GRT8120 OPERATOR MANUAL 1 8 Published 3 22 2021 Control 702 02 THIS PAGE BLANK ...
Страница 74: ...SAFETY INFORMATION GRT8120 OPERATOR MANUAL 2 50 Published 3 22 2021 Control 702 02 THIS PAGE BLANK ...
Страница 182: ...OPERATING PROCEDURES GRT8120 OPERATOR MANUAL 4 52 Published 3 22 2021 Control 702 02 FIGURE 4 54 ...
Страница 184: ...OPERATING PROCEDURES GRT8120 OPERATOR MANUAL 4 54 Published 3 22 2021 Control 702 02 FIGURE 4 55 1a 1b 1c 1d 1e 1f ...
Страница 186: ...OPERATING PROCEDURES GRT8120 OPERATOR MANUAL 4 56 Published 3 22 2021 Control 702 02 FIGURE 4 56 1a 1b 1c 1d 1e 1f 1g ...
Страница 188: ...OPERATING PROCEDURES GRT8120 OPERATOR MANUAL 4 58 Published 3 22 2021 Control 702 02 FIGURE 4 57 ...
Страница 190: ...OPERATING PROCEDURES GRT8120 OPERATOR MANUAL 4 60 Published 3 22 2021 Control 702 02 FIGURE 4 58 ...
Страница 221: ...Grove Published 3 22 2021 Control 702 02 4 91 GRT8120 OPERATOR MANUAL OPERATING PROCEDURES 4 THIS PAGE BLANK ...
Страница 378: ...5 70 Published 3 22 2021 Control 702 02 SET UP AND INSTALLATION GRT8120 OPERATOR MANUAL THIS PAGE BLANK ...
Страница 440: ...GRT8120 OPERATOR MANUAL A 10 Published 3 22 2021 Control 702 02 THIS PAGE BLANK ...
Страница 447: ......
Страница 448: ......