EN | 24 | ACX150/250 | Manual cycle
© MAHLE
After the connection, press “YES” to
proceed and follow the instructions
showed on the screen.
12
Manual cycle
The access to manual cycle can be
achieved selecting the functions in the
Manual Cycle menu.
12.1
Recovery
In the MANUAL CYCLE menu select
RECOVERY function.
Press and start the recovery function and
follow the tool instructions. If there is no
pressure inside the system, this function
cannot be started.
POSSIBLE ERROR INDICATION
Too high pressure in the A/C
service unit.
Valves or couplers closed or
system empty.
12.2
Vacuum
From the main menu select MANUAL
CYCLE and press VACUUM.
Connect the HP – LP couplers or the
single coupler to the vehicle system and
screw the couplers. Now set the time for
the vacuum and control phase, if different
from the default settings. The vacuum
phase is automatically followed by the
“vacuum test” phase.
Press START to start the vacuum phase.
POSSIBLE ERROR INDICATION
System pressurised
POSSIBLE ERROR INDICATION
System not tight
12.3
Charge
In the main menu select MANUAL CYCLE
and then CHARGE.
Set the following items :
Charge mode and quantity of oil
that will be charged into the
system
o
OIL <value> g. It
charges the quantity of
oil that has been set.
o
REC. + <value> g. It
charges the quantity of
recovered oil plus the
quantity of oil that has
been set
o
NO OIL. No oil is
charged during the
charge cycle
Oil type: It sets the oil type being
used. PAG (ISO46/100/150) or
POE
UV: Option for the charge of UV
dye
Amount of refrigerant that will be
charged into the system and the
amount of refrigerant contained
in the inner tank of the UNIT.
Charge type: It allows selecting
from which hose the service is
carried out, according to the
type of system.