115
P0692 - Low speed fan short to battery
LOW SPEED
COOLING FAN
The cooling fan is controlled by EMS ECU . The low speed cooling fan will be ON whenever A/C is
switched ON (middle pressure switch is OFF) or coolant temperature is more than 98°C and less than
101°C
COMPONENT LOCATION
NORMAL
OPERATION
Depending upon the AC ON status or coolant temperature , the EMS ECU
controls the low speed cooling fan
DTC DETECTING
CONDITION
Electrical fan driver detects short to battery
PROBABLE
CAUSES
Low speed cooling fan control signal wire short to battery
LAMP STATUS
No warning lamp indication
DTC REACTION
No reaction
HEALING
CONDITION
Ignition OFF/ON