103
BA023001-en
Possible solution
Switch off the entire system
Check the wiring of the Namur sensor on the interface module
Error code
41002
Description
One side occupied, detected on the left
Possible solution
Drive on test bench on both sides, if this error is not yet displayed (only
info via status line)
Exit from the test bench
Error code
42000
Description
Short circuit at Namur sensor Occupied right
Possible solution
Switch off the entire system
Check the wiring of the Namur sensor on the interface module
Error code
42001
Description
Cable break at Namur sensor Occupied right
Possible solution
Switch off the entire system
Check the wiring of the Namur sensor on the interface module
Error code
42002
Description
One side occupied, detected on the right
Possible solution
Drive on test bench on both sides, if this error is not yet displayed (only
info via status line)
Drive vehicle off the test bench
Error code
51000
Description
Test bench occupied at switch-on
Possible solution
Drive vehicle off the test bench
If necessary, restart the entire system
Error code
60000
Description
Different firmware
Possible solution
Update the firmware of the ZM safety controller
Update the firmware of the IFM safety controller
Restart the entire system
Error code
70000
Description
Faulty zero point value at switch-on
Содержание CONNECT Series
Страница 19: ...19 BA023001 en 2 3 2 Set up diagram Set up diagram I ...
Страница 20: ...20 BA023001 en Set up diagram II ...
Страница 22: ...22 BA023001 en 2 4 1 Wiring diagram ...
Страница 23: ...23 BA023001 en 2 4 2 Control cabinet structure Basic variant ...
Страница 24: ...24 BA023001 en 2 4 3 Control cabinet structure Full equipment ...
Страница 25: ...25 BA023001 en ...
Страница 26: ...26 BA023001 en 2 4 4 Connection and termination of the central module ZM Connection of the central module ...
Страница 53: ...53 BA023001 en ...
Страница 138: ...138 BA023001 en 13 Annex 13 1 Naming convention ...