Maguire Products, Inc.
Rev. March 5, 2018 – VBD-1000 Touchscreen
17
VBD
- Vacuum Dryer
Connect RTD Thermometers
The RTD thermometer cables are terminated on one
end with a CPC connector. The Inlet RTD cable is
marked with a red band. This is the shorter of the two
cables. Connect the cables as shown with the red
banded cable connecting to the CPC connector with
the matching red band.
Secure the Heating Hopper Inlet RTD thermometer to
the side heat inlet of the heating hopper. Secure the
cable to frame of the heating hopper.
Route the longer RTD thermometer cable up to the
exhaust port on the top of the heating hopper and
secure the RTD thermometer as shown. Secure the
cable to frame of the heating hopper.
Install Heating Hopper Level Sensor and Bracket
Install the Heating Hopper bracket and sensor on top
of Heating Hopper (as shown). Located the sensor
cable that exits the top of the VBD Heating Hopper
and attach the sensor cable to the sensor.
Содержание VBD-1000
Страница 2: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 2 VBD Vacuum Dryer...
Страница 10: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 10 VBD Vacuum Dryer...
Страница 11: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 11 VBD Vacuum Dryer...
Страница 81: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 81 VBD Vacuum Dryer High Voltage Wiring Diagrams...
Страница 82: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 82 VBD Vacuum Dryer...
Страница 83: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 83 VBD Vacuum Dryer...
Страница 84: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 84 VBD Vacuum Dryer...