Maguire Products, Inc.
Rev. March 5, 2018 – VBD-1000 Touchscreen
19
VBD
- Vacuum Dryer
Dryer External Connections
Once assembled, installation requires electrical, pneumatic air line connection and intake and
output material lines to be connected.
Compressed Air Connection
Connect an air supply to the air regulator’s IN
port using a male 1/2 ” NPT fitting.
An operating air pressure of 80 psi (5.5 bar)
while the vacuum generator is running is
required for proper operation of the Dryer.
If your air supply has oil in it, add an oil
separator (coalescing filter).
Oil in the air will combine with dust drawn from
the vacuum tank forming a paste inside the
vacuum generator. It will stop working and
require cleaning.
Observe the air pressure gauge to be sure the
pressure maintains 80 psi (5.5 bar) while the
vacuum generator is running as you check and
adjust the regulator. If pressure drops below
80 psi, adjust the regulator. If the pressure
cannot be maintained at 80 psi (5.5 bar) while
the vacuum generator is running, then the air
supply line is not adequate.
Do not supply Dryer with a lubricated air supply.
Damage to Dryer may result. Use only a clean,
dry, oil-free air supply.
Содержание VBD-1000
Страница 2: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 2 VBD Vacuum Dryer...
Страница 10: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 10 VBD Vacuum Dryer...
Страница 11: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 11 VBD Vacuum Dryer...
Страница 81: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 81 VBD Vacuum Dryer High Voltage Wiring Diagrams...
Страница 82: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 82 VBD Vacuum Dryer...
Страница 83: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 83 VBD Vacuum Dryer...
Страница 84: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 84 VBD Vacuum Dryer...