Maguire Products, Inc.
Rev. March 5, 2018 – VBD-1000 Touchscreen
33
VBD
- Vacuum Dryer
Modes of Operation
Three modes of operation (on Home Screen):
Run Dryer
,
Manual Operations, Clean Out
.
Run Dryer -
See Operation on page 23.
Manual Operations
– Options that allow direct control over specific outputs.
Operate Outputs
Alarm Audio –
OFF/ON – Operates audible alarm.
Alarm Strobe –
OFF/ON – Operates strobe.
Dry Purge Supply –
CLOSED/OPEN of dry purge supply air valve
Vac Gate Upper –
OPEN/CLOSED – Material gate above vacuum chamber.
Vac Gate Lower –
OPEN/CLOSED – visible disk shaped gate below vacuum
chamber.
Vac Cham Fill –
OPEN/CLOSED - Gate located at the base of the heating
hopper.
Vac Cham Dump –
OPEN/CLOSED – Internal gate (not visible) located at the
base of the vacuum chamber.
Vac Gen Supply –
OPEN/CLOSED – Vacuum generator supply. When
operating, the vacuum generator supply pulls a vacuum on the vacuum chamber.
Vac Gen Check –
OPEN/CLOSED – Vacuum generator check valve located on
the vacuum generator. Holds the vacuum on the vacuum chamber.
Vac Cham Purge –
OPEN/CLOSED – Located
below the vacuum generator.
When open the vacuum on the vacuum chamber is released.
Blower Test –
Operates the blower.
Blower:
OFF/ON toggle using ENTER button.
Aux:
OFF/ON toggle using ENTER button.
Fail Safe:
OFF/ON toggle using ENTER button.
T1s:
Heating Hopper inlet temp setpoint.
T1a:
Heating Hopper inlet temp actual.
Vacuum Test -
Tests the Vacuum System
Vac:
Vacuum pressure readout
Start Test:
Starts the vacuum test. Runs the vacuum generator system.
Evac Time:
Amount of time in minutes/seconds to attain the vacuum setpoint
during the current test.
Cycle:
Amount of time in minutes/seconds between vacuum generator runs
during a vacuum hold. Used to determine vacuum chamber seal integrity.
Pset:
Absolute pressure that the Vacuum Chamber will be evacuated to. See
VPL parameter.
Pdel:
The pressure difference above VPL at while the vacuum generator turns
back on. See VPD parameter.
Purge Cham:
OFF/CYC/ON
Vacuum Chamber Timed Dispense –
Opens valves for specified milliseconds.
Fill:
Fill Time of the Vacuum Chamber in milliseconds.
Dump:
Dump time of the Vacuum Chamber in milliseconds.
Содержание VBD-1000
Страница 2: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 2 VBD Vacuum Dryer...
Страница 10: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 10 VBD Vacuum Dryer...
Страница 11: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 11 VBD Vacuum Dryer...
Страница 81: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 81 VBD Vacuum Dryer High Voltage Wiring Diagrams...
Страница 82: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 82 VBD Vacuum Dryer...
Страница 83: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 83 VBD Vacuum Dryer...
Страница 84: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 84 VBD Vacuum Dryer...