Maguire Products, Inc.
Rev. March 5, 2018 – VBD-1000 Touchscreen
16
VBD
- Vacuum Dryer
Heating Hopper Dump Valve Air Lines
There is one white and one blue 5/32 inch air
line, two RTD thermometer cables and one
sensor wire (not pictured) bundled within the
VBD-1000 enclosure for safety during
shipping of the VBD-1000. The air lines and
cables must be brought through the enclosure
using the predrilled slotted keyholes. in the
top panel.
To install remove the top panel and locate the
air lines and RTD thermometer cables. On
each air line and wire is a rubber grommet.
Slide the rubber grommet into the slotted
keyhole in the sheet metal, then re-install the
top panel.
Test air line orientation:
connect air supply
to VBD-1000. With the VBD power turned off,
the air cylinder should be extended as shown
in photo to the right. Air cylinder is extended
closing the butterfly valve inside the base of
the hopper.