Maguire Products, Inc.
Rev. March 5, 2018 – VBD-1000 Touchscreen
44
VBD
- Vacuum Dryer
lag in any mechanical device.
DLA
Dump Lag Time (ms) – 00100
The time, in milliseconds, that is added to every vacuum chamber dump valve
opening operation. This compensates for the dump valve opening delay caused by
the inherent lag in any mechanical device.
VGD
Vacuum Gate Delay (Time in seconds) – 00303
Format: XXXYY - XXX = lower vacuum gate, YY = upper vacuum gate
The amount of time in seconds after a vacuum gates opens before the vacuum
chamber fill or dump valve can open. (Opening of Vacuum Chamber fill valve or
dump valve).
VFA
Vacuum Fill Adjust (Retries, percent) – 00310
Two part parameter. The first three digits are the number of retries to fill the
Vacuum Chamber (default 3 retries). Last two digits are the minimum allowable
percent under the targeted maximum fill weight of the Vacuum Chamber (VTH
parameter). After the third failed retry the “Low Batch” alarm is generated while the
VBD continues to retry.
HDD
Heat Hopper Dump Delay - Seconds - 0004
Delay in seconds between the heating system shutdown and material dump from
the heating hopper to the Vacuum Chamber. This delay allows time for the blower
to stop.
VCT
Vacuum Dump Threshold – grams/second – 00115
During a Vacuum Chamber dump (into the Retention Hopper), the material flow
rate is constantly calculated. When the flow rate reaches VTT, indicating that the
chamber is empty, the Vacuum Chamber dump valve is closed.
CDR
Chamber Dump Retries (%/Retries) – 05003
Controls the Vacuum Chamber Dump Alarm.
Format: XXXYY - XXX = percentage, YY = number of retries
When the vacuum chamber dumps material into the retention hopper, if less than
50% of the material that should have dropped is detected in the retention hopper, a
dump retry will occur. After 3 failed retries a VC DUMP alarm will trigger.
RAL
Residence Alarm – pounds / minutes - 05120
When the Residence Alarm is enabled, this parameter will determine when a
residence alarm will occur. This parameter contains two variables. The first two
digits are weight (in lbs or kgs) and the last three digits are minutes. For example,
if after 120 minutes there are less than 5 lbs (or kgs) of material removed from the
retention hopper, the Residence Alarm will sound (if enabled, see the Alarm Setup
menu).
BCH
Batch Mode – weight (lbs/kgs) – 00000
The amount of material in pounds or kilograms that will be dried during a batch run.
LTP
Loader Trip Point – weight (1/10 pound or kilogram) – 00005
If loader 2 (downstream loader) is enabled, and the amount of material in the
retention hopper is at or above this weight, the loader 2 output turns on.
Содержание VBD-1000
Страница 2: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 2 VBD Vacuum Dryer...
Страница 10: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 10 VBD Vacuum Dryer...
Страница 11: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 11 VBD Vacuum Dryer...
Страница 81: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 81 VBD Vacuum Dryer High Voltage Wiring Diagrams...
Страница 82: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 82 VBD Vacuum Dryer...
Страница 83: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 83 VBD Vacuum Dryer...
Страница 84: ...Maguire Products Inc Rev March 5 2018 VBD 1000 Touchscreen 84 VBD Vacuum Dryer...