48
41-621.1 HART
®
to Modbus
®
Adaptor Operating Manual
14.4.12
Uncheck the checkbox to stop the macro from repeating.
14.4.13
Create another Transmit Macro that will send U63?$0D and click on the Mx button to the
right of the macro definition. This causes the HMA to automatically reboot into the HART
over RS-485 mode. There shall be no response from the HMA.
14.4.14
Check the checkbox to the right of the U02?$0D macro definition.
14.4.15
Ensure that there is no response from the HMA.
14.4.16
Click on the Disconnect button.
14.4.17
Start PACTware.
14.4.18
Add a HART Comm DTM to the Project.
14.4.19
Left click on the Comm DTM in the Project tree and add a DTM to the Project for one of
the listed devices.
14.4.20
Right-click on the Comm DTM Project item and select Parameter. Select the correct COM
port for the RS-485 communications cable, set the Start address and End address to cover
the range of addresses for the attached devices. Set the Comm DTM to be a secondary
master, then click OK.