215676
122
Revision A
1023539
A
Figure 3.146: Header Height Controls on GSL
6.
Press and hold HEADER UP button (A) on the ground speed
lever (GSL).
•
CALIBRATING HEIGHT will appear on the upper line.
•
RAISE HEADER HOLD will appear on the lower line.
NOTE:
The word HOLD will flash during calibration. RAISE HEADER
DONE will display on the lower line once calibration is
complete.
7.
Release HEADER UP button (A).
•
HEIGHT SENSOR CAL will appear on the upper line.
•
PRESS LOWER HEADER will appear on the lower line.
1023540
A
Figure 3.147: Header Height Controls on GSL
8.
Press and hold HEADER DOWN button (A) on the GSL.
NOTE:
The word HOLD will flash during calibration. HT SENSOR
COMPLETE will display on the lower line once calibration is
complete.
9.
Release HEADER DOWN button (A).
•
TO CALIBRATE SELECT will appear on the upper line.
•
HEADER HEIGHT will appear on the lower line.
10. Press the right arrow to select the next header sensor calibration or select STOP & EXIT. Press SELECT.
Refer to
Calibrating Header Tilt Sensor, page 123
or
Calibrating Header Float Sensors, page 125
11. Press PROGRAM to exit programming mode.