215676
131
Revision A
1009288
CXXX
MXXX
DIAGNOSTIC MODE?
NO/YES
A
B
Figure 3.167: Diagnostic Functions
5.
Press SELECT (B) until ENTER SENSOR SETUP? appears on
the upper line.
•
NO/YES will appear on the lower line.
6.
Press right arrow (A) to select YES. Press SELECT (B).
•
KNIFE SPEED SENSOR will appear on the lower line.
•
ENABLE/DISABLE will appear on the lower line.
1009348
CXXX
MXXX
KNIFE SPEED SENSOR
ENABLE/DISABLE
C
C
B
A
D
Figure 3.168: Header Sensors
7.
Press left arrow (B) to enable the selected sensor. Press
right arrow (C) to disable the selected sensor. Press
SELECT (D) to confirm your selection and to proceed to the
next sensor.
These sensors can be enabled or disabled:
•
HEADER HT SENSOR
•
HEADER TILT SENSOR
•
KNIFE SPEED SENSOR
•
REEL SPEED SENSOR
•
HEADER FLOAT SENSOR
•
OVERLOAD PRESSURE SENSOR
19
•
HYD OIL TEMP SENSOR
Press SELECT (D) to display the EXIT SENSOR SETUP?
selection.
8.
Press right arrow (C) to select YES. Press SELECT.
9.
Press PROGRAM (A) to exit programming mode or press
SELECT to proceed to the next diagnostic option.
Displaying Header Sensor Input Signals
Review the output voltage from individual header sensors by accessing the DIAGNOSTIC MODE sub-menu in the
WINDROWER SETUP menu in the windrower
’
s cab display module (CDM).
NOTE:
The header must be attached to the windrower to perform this procedure. The CDM automatically adjusts its programming
for each header. For more information, refer to
4.5 Attaching and Detaching Headers, page 215
.
19. Requires installation of optional pressure sensor (MD #B5574).