When  deciding  upon  the  mounting  position  for  the  PIR  Detector  the  following  points  should  be 

considered to ensure trouble free operation:

1.  Do  not  position  the  PIR  Detector  facing  a  window  or  where  it  is  exposed  to  or  facing  direct 

sunlight. PIR Detectors are not suitable for use in conservatories or for external use.

.  Do not  position the  PIR Detector where  it is exposed to draughts.

3.  Do not position the PIR Detector directly above a heat source, (e.g. fire, radiator, boiler, etc).

4.  Where possible, mount the PIR Detector in the corner of the room so that the logical path of an 

intruder  would  cut  across  the  fan  detection pattern. PIR Detectors respond more effectively to 

movement across the device than to movement directly towards it.

5.  Do not locate the PIR Detector in a position where it is subject to excessive vibration.

6.  Ensure that the position selected for the PIR Detector is within effective range of the System.

Note:

 When the system is armed, pets should not be allowed into an area protected by a PIR 

Detector as their movement will trigger the PIR and generate an alarm.

Note:

 DO NOT fix the PIR Detector to metalwork or locate the unit within 1m of metalwork (i.e. 

radiators, water pipes, etc) as this could affect the radio range of the device.

Installing and Configuring the PIR Movement Detector

Ensure that the system is in Service Mode

1.  Undo and remove the fixing screw  from  the bottom edge of the PIR Detector.  Carefully pull the 

bottom edge of the PIR Detector away from the rear cover and then slide down to release the top 

clips.

Mounting Hole

 

Positions

 

Rear Cover

 

Fixing Screw

 

.  Carefully drill the required mounting holes in the rear cover using a 3mm drill relevant to whether 

the PIR Detector is being mounted in a corner or against a flat wall.

3.  Using the rear cover as a template, mark the positions of the fixing holes on the wall.

4.  Fix the rear cover to  the  wall  using  the  two 18mm No.4 screws and 5mm wall plugs, (a 5mm 

hole will be required for the wall plugs). Do  not  over-tighten  the  fixing  screws  as  this may 

distort or damage the cover.

Содержание LHK100SU

Страница 1: ...Wire Free Alarm System LHK100SU Instruction Guide For a Control Panel operated system please refer to the Operating and Installation Instructions supplied with the Control Panel...

Страница 2: ...ntact Detector 12 Installing and Configuring the Magnetic Contact Detector 12 Setting the Magnetic Contact Detector 13 Testing the Magnetic Contact Detector 14 External Solar Siren 15 Choosing a Locat...

Страница 3: ...d acid battery for the Solar Siren 3 x 9V PP3 Alkaline battery for PIR Movement Detectors and Solar Siren 5 x 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors External Solar S...

Страница 4: ...matically reset Subsequent detectors triggered will again sound the alarm If the alarm is triggered more than 3 times then it will become Locked Out and any further alarm signals will be ignored until...

Страница 5: ...ing a series of 8 DIP switches in all devices to the same ON OFF combination the House Code selected by the user installer ON ECE 1 2 3 4 5 6 7 8 e g Switch set to ON position The House Code is set up...

Страница 6: ...2 3 4 5 6 7 8 9 External Solar Siren Magnetic Contact Detector PIR Movement Detector PIR Movement Detector Remote Control Remote 1 Keypad 2 Magnetic Contact Detector SHED Back Door KITCHEN HALL DININ...

Страница 7: ...emove the front cover by undoing the small screw on the rear of the Remote Control 2 Located above the battery is a row of 8 DIP switches Select and record a random combination of ON and OFF positions...

Страница 8: ...this occurs the battery should be replaced as soon as possible Positioning the PIR Detector The recommended position for a PIR Detector is in the corner of a room mounted at a height of between 2 and...

Страница 9: ...n the system is armed pets should not be allowed into an area protected by a PIR Detector as their movement will trigger the PIR and generate an alarm Note DO NOT fix the PIR Detector to metalwork or...

Страница 10: ...the PCB of the PIR Detector are two blocks of DIP switches SW2 and SW3 When setting Dip Switches to the House Code hold the PIR Detector upside down as shown in the diagram below 1 DIP switches SW2 nu...

Страница 11: ...connected the LED behind the lens will flash for 2 3 minutes until the PIR has warmed up and stabilized The LED will then stop flashing and turn OFF Testing The PIR Detector Before testing the PIR Det...

Страница 12: ...generate an alarm condition Positioning the Magnetic Contact Detector The Magnetic Contact Detector is suitable for mounting in dry interior locations only Decide which doors windows are to be protec...

Страница 13: ...igned with the mark on the Detector 5 If an additional wired Magnetic Contact is required this should be wired to the terminal block provided in the battery compartment and the jumper link S2 below sh...

Страница 14: ...n the Detector will illuminate for approx 1 second to indicate that the tamper switch has been activated 2 Open the door window As the Magnet is moved away from the Detector the LED will illuminate fo...

Страница 15: ...city battery A Solar Panel mounted on the top of the housing charges the battery during daylight hours During darkness only a small amount of energy is required to maintain the Solar Siren unit Initia...

Страница 16: ...holes on the external wall Drill four 6mm holes and insert the plastic wall plugs Mount the back plate using the four screws provided 9 8 7 6 5 4 3 2 1 NO Solar Panel Front Cover Locating Tabs Tamper...

Страница 17: ...ver securely Once you have completed setting the Solar Siren refit the DIP switch cover and replace the three cover fixing screws Do not over tighten the screws as this could damage the thread Initial...

Страница 18: ...using the Remote Control as follows Remote Control Press and hold the button for 6 seconds The Siren will produce 2 short beeps as the button is pressed followed by a single long beep 6 seconds later...

Страница 19: ...ng the button on the Remote Control The Siren will stop and acknowledge the signal by beeping twice unless Beep Disable has been selected PIR Detectors 5 Arm the system in Instant Arm mode by pressing...

Страница 20: ...tton on the Remote Control 10 Open a door window protected by a Magnetic Contact Detector and ensure that the alarm sounds 11 Disarm the system and stop the Siren by pressing the button on the Remote...

Страница 21: ...fully Armed On returning to and entering the property by opening a protected door or moving through a PIR protected area the system will be triggered and the Siren will emit a single long beep However...

Страница 22: ...weeks depending upon system use However the battery for that device should be replaced as soon as possible Note Before replacing the battery in any device switch the system into Service Mode as previo...

Страница 23: ...w Should this occur the unit must be recharged from a 7 5 V dc 100mA supply e g from a mains adaptor power supply When re powering the Siren fit a new 9V PP3 leak proof Alkaline power up battery to en...

Страница 24: ...household or commercial waste At the end of its useful life the packaging and product should be disposed of via a suitable recycling centre Please contact your local authority or the retailer from whe...

Страница 25: ...ess Code and System House Code below e d o C e s u o H m e t s y S e d o C s s e c c A r e s U E C E N O e g ON 1 2 3 4 5 6 7 8 Use the above diagram to record your House Code This information is conf...

Страница 26: ...mote Control or Remote Keypad 1 Remote Control or Remote Keypad battery low Replace battery 2 Ensure the House Code is correctly set to the same code as all other system devices 3 Incorrect User Acces...

Страница 27: ...d Detector is less than 10mm 2 Ensure the batteries are fitted with correct polarity 3 Ensure the battery holder connections are making good contact with the batteries and PCB Circuit board 4 Ensure t...

Страница 28: ...product then 1 Contact your supplier and obtain a Return Authorisation Number 2 Adequately package your product to prevent damage in transit and include the following a A copy of your original invoice...

Страница 29: ...quency 433MHz Range Up to 100 metres Changeable 4 digit User Access code Anti Tamper protected Personal Attack PA facility Typical Battery Life 1 year Low Battery Indicator Operates all ARM PART ARM a...

Отзывы: