![LuxHome LHK100SU Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/luxhome/lhk100su/lhk100su_instruction-manual_1952214022.webp)
Disarming the System
The system can be disarmed using the Remote Control as follows:
Remote Control:
Press the
button.
The Siren will acknowledge the Disarm signal by beeping twice unless beep disable has been set.
Personal Attack (PA) Alarm
A full Alarm condition can be immediately initiated at any time (whether the system is Armed or
Disarmed) in the event of threat or danger by activating the Panic Button on the Remote Control.
Remote Control:
Slide the Panic Button upwards.
Device Tamper
If the battery cover of any device (except a Remote Control) is removed or if the Siren or Remote
Keypad are removed from the wall then an Alarm will immediately occur (unless the Siren is in
Service Mode), even if the system is Disarmed.
The Alarm will sound until the set alarm duration time expires or the system is Disarmed from the
Remote Control or Remote Keypad.
Battery Monitoring
All system devices continuously monitor their battery condition. When a low battery indicator is
activated the device will continue to operate normally for up to weeks (depending upon system
use). However, the battery for that device should be replaced as soon as possible.
Note:
Before replacing the battery in any device switch the system into Service Mode as previously
described. When the batteries have been replaced, the system should be returned to Operating
Mode. The low battery indication for each system device is as follows:
Remote Control:
When the Remote Control is operated under low battery conditions the transmit LED will continue
to flash after the button has been released.
Under normal battery conditions the LED will extinguish within seconds of the button being
released.
PIR Movement Detectors:
Under low battery conditions the LED behind the detector lens will flash when movement is
detected to indicate that the battery needs to be replaced.
Under normal battery conditions the LED does not illuminate unless the PIR Detector is in Walk
Test mode.
Magnetic Contact Detectors:
When the Detector is activated, under low-battery conditions the Transmit LED will be illuminated
for approximately 1 second as the door/window is opened.
Under normal battery conditions the LED does not illuminate as the Detector is operated, unless
the Detector is in Test Mode with the battery cover removed.