10
Note:
The wall plugs supplied with the product are not suitable for plasterboard walls, if
mounting the PIR Detector onto plasterboard use appropriate wall plugs.
5. Configure the PIR Detector as described in ‘Setting the PIR Detectors’. Remember that on initial
installation the device needs to be tested and should therefore be set in Walk Test Mode.
6. Check that the PIR Detector PCB is located and set in the correct position to give the detection
zone pattern required.
To adjust the PCB position, simply slide it up or down ensuring that the location legs are aligned
with the required position number marked on the board.
7. To refit the PIR Detector to the rear cover, offer it up to the rear cover and locate the clips in the
top edge into the rear cover. Push the lower edge of the PIR Detector into place and refit the fixing
screw in the bottom edge to secure in position. Do not over-tighten the fixing screw as this may
damage the casing.
Setting the PIR Detector
Located on the PCB of the PIR Detector are two blocks of
DIP switches (SW and SW3).
When setting Dip Switches to the House Code, hold the PIR
Detector ‘upside down’ as shown in the diagram below:
1. DIP switches SW (numbered 1-8) are used to set the
House Code for the PIR Detector and must be set to the
same ON/OFF combination as the House Code DIP
switches in all other system devices.
Setting for a Siren only Alarm System
For this alarm system the DIP switches 1- 3 of SW3
must be set as follows:
DIP 1
DIP 2
DIP 3
ON
ON
OFF
. DIP 4 of SW3 is used to configure the PIR Detector for walk test mode, which allows the operation
of the Detector to be checked during installation without triggering a Full Alarm.
DIP 4 of SW3
Mode
Trigger reaction on LED
ON
Walk
Test
• LED single flash when movement
detected: implies the sensor is set
to high sensitivity
• LED flashes three times and
illuminates once: implies the
sensor is set to low sensitivity
OFF
Normal Position
LED will not light up (unless the
battery in the PIR is low)
DIP Switches
(SW2 and SW3)
PCB Board
(slides up and
down to adjust
position)
SW2
E
C
E
N
O
SW3
ON
ECE
1 2 3 4 5 6 7 8
1 2 3 4 5
Set to House Code
Zone
Settings
Walk Test Sensitivity