LuxHome LHK100SU Скачать руководство пользователя страница 15

15

External Solar Siren

Siren Housing

The  Siren,  Strobe  Light  and  Solar  Panel  are  all  encapsulated 

within  a  tough  polycarbonate  housing.  This  housing  provides 

full  protection  against  adverse  weather  conditions. All  electronic 

components are specially treated to ensure long, reliable, trouble 

free  operation  and  an  integral  tamper  switch  gives  maximum 

security protection to the unit.

An  LED  indicator  unit  is  built  into  the  Siren  to  act  as  a  visible 

deterrent  and  indication  that  the  system  is  active.  The  LEDs 

will  slowly  and  alternately  flash  whether  the  system  is  Armed 

or  Disarmed.  When  an  alarm  occurs  the  LEDs  will  flash  rapidly 

together.

An  integral  tamper  switch  provides  additional  security  protection 

to  the  Siren  and  will  immediately  trigger  an  alarm  should  any 

unauthorised  attempt  be  made  to  interfere  with  and  remove  the 

Siren cover, (unless the Siren is in Service Mode).

Rechargeable Battery

The Solar Siren is powered by a high capacity battery. A Solar Panel mounted on the top of the 

housing charges the battery during daylight hours. During darkness, only a small amount of energy 

is required to maintain the Solar Siren unit.

Initial Power-Up Battery

An Alkaline 9V PP3 battery is supplied in the Siren & Strobe unit to provide the initial power to the 

system.

Siren Code

An encrypted code is set using a combination of miniature DIP switches. This enables you to select 

a unique security code for your installation.

Choosing a Location for the Solar Siren

The Siren & Strobe unit should be fitted to the outside 

of the building in a position that is clearly visible and at 

a height which is relatively inaccessible to an intruder.

Although the Siren & Strobe is designed to work on any 

aspect wall, you should refrain from fixing the unit on a 

North facing wall where possible.

Shadows  cast  by  neighbouring  walls,  trees  and  roof 

overhangs  should  also  be  avoided.  In  practice,  the 

Siren  &  Strobe  should  be  positioned  a  minimum  of 

twice  the  width  of  the  eaves  overhang,  below  the 

eaves.  Remember  that  in  winter  the  sun  is  lower  in 

the sky and you should avoid winter shadows where 

possible.

Содержание LHK100SU

Страница 1: ...Wire Free Alarm System LHK100SU Instruction Guide For a Control Panel operated system please refer to the Operating and Installation Instructions supplied with the Control Panel...

Страница 2: ...ntact Detector 12 Installing and Configuring the Magnetic Contact Detector 12 Setting the Magnetic Contact Detector 13 Testing the Magnetic Contact Detector 14 External Solar Siren 15 Choosing a Locat...

Страница 3: ...d acid battery for the Solar Siren 3 x 9V PP3 Alkaline battery for PIR Movement Detectors and Solar Siren 5 x 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors External Solar S...

Страница 4: ...matically reset Subsequent detectors triggered will again sound the alarm If the alarm is triggered more than 3 times then it will become Locked Out and any further alarm signals will be ignored until...

Страница 5: ...ing a series of 8 DIP switches in all devices to the same ON OFF combination the House Code selected by the user installer ON ECE 1 2 3 4 5 6 7 8 e g Switch set to ON position The House Code is set up...

Страница 6: ...2 3 4 5 6 7 8 9 External Solar Siren Magnetic Contact Detector PIR Movement Detector PIR Movement Detector Remote Control Remote 1 Keypad 2 Magnetic Contact Detector SHED Back Door KITCHEN HALL DININ...

Страница 7: ...emove the front cover by undoing the small screw on the rear of the Remote Control 2 Located above the battery is a row of 8 DIP switches Select and record a random combination of ON and OFF positions...

Страница 8: ...this occurs the battery should be replaced as soon as possible Positioning the PIR Detector The recommended position for a PIR Detector is in the corner of a room mounted at a height of between 2 and...

Страница 9: ...n the system is armed pets should not be allowed into an area protected by a PIR Detector as their movement will trigger the PIR and generate an alarm Note DO NOT fix the PIR Detector to metalwork or...

Страница 10: ...the PCB of the PIR Detector are two blocks of DIP switches SW2 and SW3 When setting Dip Switches to the House Code hold the PIR Detector upside down as shown in the diagram below 1 DIP switches SW2 nu...

Страница 11: ...connected the LED behind the lens will flash for 2 3 minutes until the PIR has warmed up and stabilized The LED will then stop flashing and turn OFF Testing The PIR Detector Before testing the PIR Det...

Страница 12: ...generate an alarm condition Positioning the Magnetic Contact Detector The Magnetic Contact Detector is suitable for mounting in dry interior locations only Decide which doors windows are to be protec...

Страница 13: ...igned with the mark on the Detector 5 If an additional wired Magnetic Contact is required this should be wired to the terminal block provided in the battery compartment and the jumper link S2 below sh...

Страница 14: ...n the Detector will illuminate for approx 1 second to indicate that the tamper switch has been activated 2 Open the door window As the Magnet is moved away from the Detector the LED will illuminate fo...

Страница 15: ...city battery A Solar Panel mounted on the top of the housing charges the battery during daylight hours During darkness only a small amount of energy is required to maintain the Solar Siren unit Initia...

Страница 16: ...holes on the external wall Drill four 6mm holes and insert the plastic wall plugs Mount the back plate using the four screws provided 9 8 7 6 5 4 3 2 1 NO Solar Panel Front Cover Locating Tabs Tamper...

Страница 17: ...ver securely Once you have completed setting the Solar Siren refit the DIP switch cover and replace the three cover fixing screws Do not over tighten the screws as this could damage the thread Initial...

Страница 18: ...using the Remote Control as follows Remote Control Press and hold the button for 6 seconds The Siren will produce 2 short beeps as the button is pressed followed by a single long beep 6 seconds later...

Страница 19: ...ng the button on the Remote Control The Siren will stop and acknowledge the signal by beeping twice unless Beep Disable has been selected PIR Detectors 5 Arm the system in Instant Arm mode by pressing...

Страница 20: ...tton on the Remote Control 10 Open a door window protected by a Magnetic Contact Detector and ensure that the alarm sounds 11 Disarm the system and stop the Siren by pressing the button on the Remote...

Страница 21: ...fully Armed On returning to and entering the property by opening a protected door or moving through a PIR protected area the system will be triggered and the Siren will emit a single long beep However...

Страница 22: ...weeks depending upon system use However the battery for that device should be replaced as soon as possible Note Before replacing the battery in any device switch the system into Service Mode as previo...

Страница 23: ...w Should this occur the unit must be recharged from a 7 5 V dc 100mA supply e g from a mains adaptor power supply When re powering the Siren fit a new 9V PP3 leak proof Alkaline power up battery to en...

Страница 24: ...household or commercial waste At the end of its useful life the packaging and product should be disposed of via a suitable recycling centre Please contact your local authority or the retailer from whe...

Страница 25: ...ess Code and System House Code below e d o C e s u o H m e t s y S e d o C s s e c c A r e s U E C E N O e g ON 1 2 3 4 5 6 7 8 Use the above diagram to record your House Code This information is conf...

Страница 26: ...mote Control or Remote Keypad 1 Remote Control or Remote Keypad battery low Replace battery 2 Ensure the House Code is correctly set to the same code as all other system devices 3 Incorrect User Acces...

Страница 27: ...d Detector is less than 10mm 2 Ensure the batteries are fitted with correct polarity 3 Ensure the battery holder connections are making good contact with the batteries and PCB Circuit board 4 Ensure t...

Страница 28: ...product then 1 Contact your supplier and obtain a Return Authorisation Number 2 Adequately package your product to prevent damage in transit and include the following a A copy of your original invoice...

Страница 29: ...quency 433MHz Range Up to 100 metres Changeable 4 digit User Access code Anti Tamper protected Personal Attack PA facility Typical Battery Life 1 year Low Battery Indicator Operates all ARM PART ARM a...