![LuxHome LHK100SU Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/luxhome/lhk100su/lhk100su_instruction-manual_1952214017.webp)
17
House Code
Under the corner cover you will find a series of 9 DIP
switches.
DIP switches 1- 8 are used to set the House Code for the
siren and must be set to the same ON/OFF combination as
all other system devices.
Note:
When the Solar Siren is viewed as shown above
(Solar panel at top) the DIP switches are ‘upside down’.
Alarm Duration Limit
This is the maximum length of time that the Solar Siren will sound for when activated under an alarm
condition. The alarm duration can be set for either 1 or 3 minutes. Set dip switch 9 as follows:
OFF
1 minute limit
ON
3 minutes
Beep Disable
The Solar Siren will acknowledge Arm and Disarm signals from the Remote Control by beeping once
for Arm and twice for Disarm. It is possible to disable the beeps if required by removing the jumper
link P on the circuit board.
Siren Disable
If for any reason you need to disable the Siren, remove jumper link P3 on the circuit board. This
will prevent the Siren from sounding during an alarm condition. However, the Siren will still beep to
acknowledge signals from the Remote Control, (provided the beep feature is not disabled).
Refit the dip switch cover securely.
Once you have completed setting the Solar Siren, refit the DIP switch cover and replace the three
cover fixing screws. Do not over tighten the screws as this could damage the thread.
Initial Power-Up of the Solar Siren
1. Connect the 9V PP3 initial power battery to the battery clip.
Connect the rechargeable battery to the charging leads. Connect the Red lead to the Red (+)
terminal and the Black lead to the Black (-) terminals.
Note:
Once the batteries have been connected, the Siren will be operational and it is important
that the Solar panel receives sufficient light to maintain the battery charge. The Siren should not
be operated repeatedly during installation and testing, as this will rapidly drain the battery. It is
recommended that the Siren be left for at least a day in order to charge the battery before the
system is armed.
. Press the anti-tamper switch, the LEDs will flash together to indicate that the unit is operational.
3. Hinge the front cover locating tabs over the top edge of the back plate and carefully push the base
of the siren cover into place. Secure the siren cover in place by refitting the fixing screw in the
bottom edge of the cover. Do not over tighten the screw as this could damage the thread.
Alarm Duration DIP switch 9
ON
1
2
3
4
5
6
7
8
9
House Code
(Always change from the factory setting)