Testing the System
Testing an Installed System
The system should be tested at regular intervals (at least every 3 months) to ensure that it is
operating correctly.
1. Before commencing testing please ensure the following:
– The Siren is in Operating Mode and Disarmed
– There is no movement or people/pets in any PIR protected area
– All doors/windows protected by Magnetic Contact Detectors are closed
– All battery covers and housings are correctly fitted
Remote Control:
. Press the
button on the Remote Control. The Siren will beep once.
3. Activate the PA switch on the Remote Control by sliding it upward.
The alarm will sound.
4. Stop the alarm by pressing the
button on the Remote Control.
The Siren will stop and acknowledge the signal by beeping twice (unless Beep Disable has been
selected).
PIR Detectors:
5. Arm the system in Instant-Arm mode by pressing
button on the Remote Control.
The Siren will acknowledge the signal by beeping once, (unless Beep Disable has been
selected).
6. Ensure that the area protected by the PIR has been free from movement for at least minutes
and then walk into the area to trigger the detector.
Note:
To conserve power the PIR will only detect movement if there has been no movement
detected within the previous minutes.
7. Stop the alarm and Disarm the system by pressing
on the Remote Control.
The Siren will stop and acknowledge the signal by beeping twice, (unless Beep Disable has
been selected).
8. Continue to test all PIR Detectors in turn as described above (steps 5 - 7).