P30P-09A 71 User's manual
4300
r
0...9999 Software version * 100
4301
r
0...9999 Bootloader version * 100
4302
r
0...65535 Status no. 1 of the transducer. Describes the current status of the
transducer. Successive bits represent the event. Bit set to 1 indicates
that the event took place. The events can be only deleted.
Bit15 31
Loss of the calibration parameters
Bit14 30
Real Time Clock – loss of settings – battery failure
Bit13 29
Clock – daylight saving on/off
Bit12 28
No communication with data memory
Bit11
27
Invalid settings
Bit10 26
Default settings restored
Bit9
25
-
Bit8
24
Internal archive communication error
Bit7
23
Archive parameters error
Bit6
22
No synchronization signal
Bit5
21
Internal archive 100% full
Bit4
20
Reset to default settings necessary
Bit3
19
Bit2
18
not used
Bit1
17
not used
Bit0
16
not used
4303
r
0...65535 Status no. 2 of the transducer. Describes the current status of the
transducer. Successive bits represent the event. Bit set to 1 indicates
that the event took place. The events can be only deleted.
Bit15
not used
Bit14
not used
Bit13
not used
Bit12
not used
Bit11
not used
Bit10
not used
Bit9
not used
Bit8
not used
Bit7
not used
Bit6
Overrun of output 1 enabled
Bit5
LED2 – Alarm signal no. 2.
Bit4
LED1 – Alarm signal no. 1.
Bit3
not used
Bit2
not used
Bit1
State of the alarm 2 relay.
Bit0
State of the alarm 1 relay.
4304
r
0...5
Memory card status