Step 4:
ED7C723-30 Group 14(). Patch the P167/P161 connector of the cable
assembly to the J167/J161 jack of the ARM backplane (DS1 IN). Secure
the connection with the attached connector screws.
Step 5:
ED7C723-30 Group 16(). Patch the P168/P160 connector of the cable
assembly to the J168/J160 jack of the ARM backplane (DS1 IN). Secure
the connection with the attached connector screws.
Step 6:
Route these two cable assemblies up over the top of the ARM shelf, over
the top of the first two cable assemblies and then towards the right (as
viewed from the rear of the shelf). The ferrite beads should not lay upon
each other. Refer to Figure 3-19.
Step 7:
Secure all four cable assemblies together with cable ties using the top of
the ARM shelf’s tie points. Refer to Figure 3-19.
Step 8:
Let the cable J165 to J168 or J160 to J163 connectors dangle in the
duct for future connections to the mating DSX cables.