Configuring Dial-In Users
7-7
Configuring Network Users
Table 7-2 describes the results of using each keyword.
Setting the Asynchronous Character Map
The PPP protocol supports the replacement of nonprinting ASCII data in the PPP stream.
These characters are not sent through the line, but instead are replaced by a special set
of characters that the remote site interprets as the original characters. The PPP
asynchronous map is a bit map of characters that should be replaced. The lowest-order
bit corresponds to the first ASCII character NUL, and so on. In most environments, the
asynchronous map should be set to zero to achieve maximum throughput.
To set the PPP asynchronous character map, use the following command:
Command>
set user
Username
map
Hex
Setting the MTU Size
The maximum transmission unit (MTU) defines the largest frame or packet that can be
sent without fragmentation. A packet that exceeds this value is fragmented, if IP, or
discarded if IPX. PPP connections can have a maximum MTU of 1520 bytes. SLIP
connections can have a maximum MTU of 1006 bytes. PPP can negotiate smaller MTUs
when requested by the calling party.
Table 7-2
Keywords for Configuring RIP Routing
Keyword
Description
on
The PortMaster broadcasts and listens for RIP information.
off
The PortMaster neither broadcasts nor listens for RIP
information from the local Ethernet. This is the default.
broadcast
The PortMaster broadcasts RIP information to the host at the
other end of the connection.
listen
The PortMaster listens for RIP information from the host or
other router.
Содержание PortMaster
Страница 16: ...Contents xvi Configuration Guide for PortMaster Products...
Страница 26: ...Subscribing to PortMaster Mailing Lists xxvi PortMaster Configuration Guide...
Страница 32: ...Basic Configuration Steps 1 6 PortMaster Configuration Guide...
Страница 114: ...Configuring WAN Port Settings 6 12 PortMaster Configuration Guide...
Страница 128: ...Configuring Login Users 7 14 PortMaster Configuration Guide...
Страница 158: ...Restricting User Access 9 16 PortMaster Configuration Guide...
Страница 168: ...Configuring Ports for Modem Use 10 10 PortMaster Configuration Guide...
Страница 222: ...Frame Relay Subinterfaces 13 16 PortMaster Configuration Guide...
Страница 236: ...Troubleshooting a Synchronous V 25bis Connection 14 14 PortMaster Configuration Guide...
Страница 252: ...Using ISDN for On Demand Connections 15 16 PortMaster Configuration Guide...
Страница 264: ...Using ISDN for Internet Connections 16 12 PortMaster Configuration Guide...
Страница 276: ...Configuration Steps for Dial In Access 17 12 PortMaster Configuration Guide...
Страница 286: ...Configuration Steps for Shared Device Access 18 10 PortMaster Configuration Guide...
Страница 296: ...Troubleshooting a Leased Line Connection 19 10 PortMaster Configuration Guide...
Страница 310: ...B 4 PortMaster Configuration Guide...
Страница 352: ...Command Index Command Index 6 PortMaster Configuration Guide...