Using Synchronous Leased Lines
19-5
Configuration Steps for Leased Line Connections
After you configure the Ethernet interface as shown in Table 19-2, enter the following
command to save the configuration:
Command>
save
all
For more information on Ethernet settings, refer to Chapter 4, “Configuring the
Ethernet Interface.”
Configuring Synchronous WAN Port Settings
Configure the synchronous WAN port on the PortMaster Office Router in Rome with
the values shown in Table 19-3. Port S1 is used in this example. The IP address for the
port is left unconfigured, accepting the default IP address value of 0.0.0.0.
If you are not sure of the IP address on the other end of the connection, you can set the
IP destination to 255.255.255.255 and the PortMaster will attempt to learn the address.
Leave all other settings at their default values.
After you configure the port S1 as shown in Table 19-3, enter the following command to
reset the port and save the configuration:
Command>
reset
s1
Command>
save
all
For more information about synchronous ports, refer to Chapter 6, “Configuring a
Synchronous WAN Port.”
Table 19-3
Synchronous WAN Port Values
Setting
Command
Port type
set
s1
network
hardwired
Transport protocol
set
s1
protocol
ppp
IP destination
set
s1
destination
192.168.1.1
Netmask
set
s1
netmask
255.255.255.0
IPX network
set
s1
ipxnet
F3
Modem control
set
s1
cd
off
RIP routing
set
s1
rip
on
MTU
set
s1
mtu
1500
Содержание PortMaster
Страница 16: ...Contents xvi Configuration Guide for PortMaster Products...
Страница 26: ...Subscribing to PortMaster Mailing Lists xxvi PortMaster Configuration Guide...
Страница 32: ...Basic Configuration Steps 1 6 PortMaster Configuration Guide...
Страница 114: ...Configuring WAN Port Settings 6 12 PortMaster Configuration Guide...
Страница 128: ...Configuring Login Users 7 14 PortMaster Configuration Guide...
Страница 158: ...Restricting User Access 9 16 PortMaster Configuration Guide...
Страница 168: ...Configuring Ports for Modem Use 10 10 PortMaster Configuration Guide...
Страница 222: ...Frame Relay Subinterfaces 13 16 PortMaster Configuration Guide...
Страница 236: ...Troubleshooting a Synchronous V 25bis Connection 14 14 PortMaster Configuration Guide...
Страница 252: ...Using ISDN for On Demand Connections 15 16 PortMaster Configuration Guide...
Страница 264: ...Using ISDN for Internet Connections 16 12 PortMaster Configuration Guide...
Страница 276: ...Configuration Steps for Dial In Access 17 12 PortMaster Configuration Guide...
Страница 286: ...Configuration Steps for Shared Device Access 18 10 PortMaster Configuration Guide...
Страница 296: ...Troubleshooting a Leased Line Connection 19 10 PortMaster Configuration Guide...
Страница 310: ...B 4 PortMaster Configuration Guide...
Страница 352: ...Command Index Command Index 6 PortMaster Configuration Guide...