Contact Closure Operation Type (#613)
Description
This System Programming procedure specifies how long the Contact Closures
remain active when they are activated. A Contact Closure can be activated for
1, 3, or 5 seconds; or the Contact Closure can be set to toggle.
If a Contact Closure that controls a door lock has a Contact Closure Operation
Type of “5-Seconds On,” for example, the door lock is released for 5 seconds
when a user activates the Contact Closure. If the Contact Closure has a Contact
Closure Operation Type of “Toggle,” the Contact Closure must be activated and
deactivated. One user can activate the Contact Closure and another user can
deactivate it (provided both users are included in the Contact Closure Group for
that Contact Closure), or the same user can both activate and deactivate the
Contact Closure. (For more information about Contact Closure devices, see
“Contact Closure Devices” in Chapter 4.)
Related Features
Before a user can activate a contact closure, you must assign the user’s
extension to the
for that Contact Closure.
When a user’s extension is included in the appropriate Contact Closure
Group, the user can then use
to activate the contact
closure device.
Valid Entries
1 = 1-Second On
2 = 3-Seconds On
✔
3 = 5-Seconds On
4 = Toggle
Programming
(See Figure 2-3 in Chapter 2 for the location of special programming buttons
such as
s
and
e
on system phones.)
To specify the Operation Type for a Contact Closure:
1.
Press
f 0 0 s s # 6 1 3
at extension 10
or 11.
2.
At the
Contact Number:
prompt, enter the number (1 or 2) for the Contact
Closure. For example, to specify Contact Closure 1, press
1
.
The display shows the current setting for that contact closure.
3.
Press
D
or
d
until the appropriate value displays, or press
r
to return to the default setting.
4.
To assign the Operation Type for the other Contact Closure, press
n
or
p
, and repeat Step 3.
5.
Select another procedure or exit programming mode.
5-54
Contact Closure Operation Type (#613)
Содержание PARTNER Advanced Communications System Release 1.0
Страница 6: ...iv...