POTENZE IMPEGNATE POTENZE IMPEGNATE PER I VENTILATORI TRIFASE MONTATI SUI CONDENSATORI SDHV O RAFFREDDATORI DI LIQUIDO SDHL
POWER DRAWN BY THREE PHASE VENTILATOR MOTORS INSTALLED ON SDHV CONDENSERS OR SDHL DRY COOLERS
PUISSANCES UTILISEES PAR LES VENTILATEURS TRIPHASES MONTES SUR LES CONDESEURS SDHV OU LES AEROREFRIGERANTS SDHL
STROMAUFNAHME FÜR DIE IN DEM VERFLÜSSIGERN SDHV BZW. FLÜSSIGKEITSRÜCKKÜHLERN SDHL EINGEBAUTEN DREHSTROMVENTILATOREN
Ventilatori / Fans / Ventilateurs / Ventilatoren
FE 1000 12P
MODELLO QUADRO ELETTRICO
TYPE CONTROL BO
X
MODELE COFFRET ELECTRIQUE
MODELL SCHAL
TSCHRANK
N
°
VENTILA
T
ORI
F
ANS NUMBER
NBRE VENTILA
TEURS
ANZAHL VENTILA
T
OREN
MODELLO REGOLA
T
ORE ELETTRONICO
TYPE ELECTRONIC CONTROLLER
MODELE REGULA
TEUR ELECTRONIQUE
MODELL ELEKTRONISCHE
P
O
R
TATA
FUSIBILI
FUSES RA
TING
CAP
ACITE’ DES FUSIBLES
ABSICHERUNNG
N
°
VENTILA
T
ORI PER CONT
A
T
T
ORE
N
°
F
ANS FOR CONT
ACT
OR
N
°
VENTILA
TEURS POUR CONT
ACTEURS
N
°
VENTILA
T
OREN MIT SCHÜTZE
N
°
CONT
A
T
T
ORI
N
°
CONT
ACT
OR
N
°
CONT
ACTEURS
N
°
SCHÜTZE
N
°
VENTILA
T
ORI PER BASE FUSIBILI
N
°
F
ANS FOR FUSESBASE
N
°
VENTILA
TEURS POUR BASE FUSIBLES
N
°
VENTILA
T
OREN
MIT
........
(A)
N
°
N
°
N
°
(A)
QE...
FU1 FU2 FU3
FU1*
FU2
FU3
RUS
1x1
1
1
1,5
1/20A
1
-
-
4
-
-
8
1x2
1
2
3
2/20A
2
-
-
4
-
-
8
1x3
1
3
4,5
3/20A
3
-
-
6
-
-
8
1x4
1
4
6
4/20A
4
-
-
8
-
-
16
1x5
1
5
7,5
5/20A
5
-
-
10
-
-
16
1x6
1
6
9
6/20A
6
-
-
12
-
-
16
1x7
1
7
10,5
7/20A
7
-
-
16
-
-
16
ASSORBIMENT
O T
O
TALE
T
O
TAL CONSUMPTION
PUISSANCE T
O
TAL
AUFNAHMEGESAMT
Ventilatori / Fans / Ventilateurs / Ventilatoren
FC 900 6P
MODELLO QUADRO ELETTRICO
TYPE CONTROL BO
X
MODELE COFFRET ELECTRIQUE
MODELL SCHAL
TSCHRANK
N
°
VENTILA
T
ORI
F
ANS NUMBER
NBRE VENTILA
TEURS
ANZAHL VENTILA
T
OREN
MODELLO REGOLA
T
ORE ELETTRONICO
TYPE ELECTRONIC CONTROLLER
MODELE REGULA
T
EUR ELECTRONIQUE
MODELL ELEKTRONISCHE
P
O
R
TATA
F
U
S
IB
IL
I
FUSES RA
TING
CAP
ACITE’ DES FUSIBLES
ABSICHERUNNG
N
°
VENTILA
T
ORI PER CONT
A
T
T
ORE
N
°
F
ANS FOR CONT
ACT
O
R
N
°
VENTILA
TEURS POUR CONT
ACTEURS
N
°
VENTILA
T
OREN MIT SCHÜTZE
N
°
CONT
A
T
T
ORI
N
°
CONT
ACT
OR
N
°
CONT
ACTEURS
N
°
SCHÜTZE
N
°
VENTILA
T
ORI PER BASE FUSIBILI
N
°
F
ANS FOR FUSESBASE
N
°
VENTILA
TEURS POUR BASE FUSIBLES
N
°
VENTILA
T
OREN
MIT
........
(A)
N
°
N
°
N
°
(A)
QE...
FU1* FU2 FU3
FU1*
FU2
FU3
RUS
1x1
1
1
6,3
1/20 A
1
-
-
8
-
-
16
1x2
-
-
-
-
-
-
-
-
-
-
-
1x3
-
-
-
-
-
-
-
-
-
-
-
1x4
-
-
-
-
-
-
-
-
-
-
-
1x5
-
-
-
-
-
-
-
-
-
-
-
1x6
-
-
-
-
-
-
-
-
-
-
-
1x7
-
-
-
-
-
-
-
-
-
-
-
ASSORBIMENT
O T
O
TALE
T
O
TAL CONSUMPTION
PUISSANCE T
O
TAL
AUFNAHMEGESAMT
N
°
N
°
N
°
(A)
QE...
FU1 FU2 FU3
FU1*
FU2
FU3
RUS
1x1
1
1
3,5
1/20 A
1
-
-
6
-
-
8
1x2
1
2
7
2/20 A
2
-
-
10
-
-
16
1x3
1
3
10,5
3/20 A
3
-
-
16
-
-
16
1x4
-
-
-
-
-
-
-
-
-
-
-
1x5
-
-
-
-
-
-
-
-
-
-
-
1x6
-
-
-
-
-
-
-
-
-
-
-
1x7
-
-
-
-
-
-
-
-
-
-
-
N
°
N
°
N
°
(A)
QE...
FU1 FU2 FU3
FU1*
FU2
FU3
RUS
1x1
1
1
0,8
1/20 A
1
-
-
2
-
-
8
1x2
1
2
1,6
2/20 A
2
-
-
4
-
-
8
1x3
1
3
2,4
3/20 A
3
-
-
4
-
-
8
1x4
1
4
3,2
4/20A
4
-
-
4
-
-
8
1x5
1
5
4
5/20A
5
-
-
6
-
-
8
1x6
1
6
4,8
6/20A
6
-
-
6
-
-
8
1x7
1
7
5,6
7/20A
7
-
-
8
-
-
8
Ventilatori / Fans / Ventilateurs / Ventilatoren
FE 900 12P
Ventilatori / Fans / Ventilateurs / Ventilatoren
FE 900 6P
Ventilatori / Fans / Ventilateurs / Ventilatoren
Ø 900 - Ø 1000 mm
Su ogni contattore sono collegati 2
ventilatori in parallelo.
Two parallel fans are wired on each
contactor.
Chaque contacteur contrôle deux
ventilateurs en parallèle.
Sind swei Ventilatoren parallel auf elnen
Schütz verdrahtet.
Ma
Mb
Tk
Tk
~
~
Tk
Alla rete / To mains
Auréseau / Zum Netz
13
RUS
NOTA:
per QE.../20A FU7 si chiama FU1
NOTE:
for QE...20/A FU7 is FU1
NOTE:
pour QE...20/A FU7 est FU1
ANMERKUNG: für QE.../20A FU7 ist FU1