FURTHER ACTIONS MAY BE REQUIRED AFTER CHANGING CERTAIN SETTINGS
Modifications on system and expanders settings may imply that you will have to take further programming or re
-
linking actions.
These actions will be notified to you from the onboard interface, nevertheless some words will be spent here:
-
if you change certain system settings, all expanders need a programming action to be performed on each of them.
-
If you change certain expander settings that are not expander 1 (that is not the central node), you will need to perform a
“
program expander
”
action for that expander; programming is not automatic and must be made manually.
-
Modification of the field channel pair on a network device, makes necessary to program that network device and link again its child
devices (if any, already linked).
-
Modification of the field channel pair of the central node, makes necessary to link again its child devices (if any, already linked).
Notification for further actions follows the selection of the
Save
command and is notified to the user via the following screens:
-
system settings change:
All expanders need to be programmed.
-
Remote expander (not expander 1, the central node) settings change:
That specific expander needs programming.
-
Field channel pair of a remote expander modified:
Program that expander and link its child devices again.
-
Field channel pair of the central node modified:
Link the central node
’
s child devices again.
Yes
and
No
options mean:
Save will require to
program all expander
Yes No
Save will require
new program
Yes No
Save will require
new prog. and link.
Yes No
Yes
You confirm your changes.
No
You do not confirm the changes you made. You can discard them by exiting the changes menu.
Save will require
new link.
Yes No