Timing
Clarity
Operator Manual
Page 96
Position filter has been selected.
The lower Timing Control still controls IPCB (Intensity, Position, Colour, Beam) but the new
Timing Control above it has been filtered for P (Position) information only. No change has yet
been made and the new Timing Control is only temporary as indicated by the paler colour and
the menu button on the Timing mode changing to “Confirm” or presence of the “?” button in
the top left corner of the Timing tab. Selecting
Confirm
or the “
?
” button or dragging in the
new Timing Control to change the time will “lock in” the timing.
The right Timing Control now only controls ICB and the left Timing Control has taken control of
P (Position) timing. You can now set the Position timing independently of the ICB timing.
16.7.1
Combining Filters
Combinations of the Filters Attribute groups of
I
ntensity,
P
osition,
C
olour and
B
eam groups can
be selected by using
Function
+ click to select and or de-select them.
Individual attributes within a group can be selected by selecting
Choose
then selecting the
attributes. Combinations of individual attributes can be selected by using
Function
+ click to
select and or de-select them.
Position and Beam have been filtered.
Pan only from the Position group has been filtered.