Chapter 7 - Options
156
7.1.2
Terminal Configuration
VR
V2
5G
NC
Q1
Q2
Q3 EXTG NC
P4
P5
P6
LM CM
7.1.3
Terminal Description
Section
Terminal
Name
Description
P4, P5, P6
Multi-Function Input
Used as the extended function of P1, P2, P3
(I/O-12 ~ I/O-14)
Contact Input
CM
Common Terminal
Common terminal for P4, P5, P6
VR
Power Supply for V2
DC voltage output terminal for V2 (+12V, 10mA)
V2
Analog Voltage Input
Analog voltage input terminal for frequency reference or override.
In
pu
t
Analog
Frequency
Reference
5G
Common Terminal
Common terminal for VR and V2
LM
Load Meter
Used to monitor one of Output Frequency, Output Current, Output
Voltage, DC link Voltage.
(+15V Pulse output, Average voltage: 0 ~ 10V DC)
+15V Pulse
Output
CM
Common Terminal
Common terminal for LM
Q1, Q2, Q3
Multi-Function Output
(Open-Collector Output)
Used as the extended function of AXA, AXC (I/O-44)
O
ut
pu
t
Open Collector
Output
EXTG
External Common Terminal Common terminal for Q1, Q2, Q3
NC
Not Used
7.1.4
Parameters of Sub-A Board
Code
Parameter Description
Code
Parameter Description
EXT-01 Sub Board Type Display
EXT-09
EXT-02
EXT-10
Analog Voltage Input Signal (V2) Adjustment
EXT-03
EXT-30
EXT-04
Multi-Function Input Terminal (P4, P4, P6) Define
EXT-31
EXT-05 V2 Mode Selection
EXT-32
Multi-Function Output Terminal (Q1, Q2, Q3)
Define
EXT-06 Filtering Time Constant for V2 Input Signal
EXT-34
EXT-07
EXT-35
LM Output Adjustment
EXT-08
Analog Voltage Input Signal (V2) Adjustment
+24V DC
24V
Ground
Содержание SV008iS5-2
Страница 28: ...Chapter 1 Installation 22 Notes ...
Страница 84: ...Chapter 5 Parameter List 78 Notes ...
Страница 92: ...Chapter 6 Parameter Description DRV 86 Notes ...
Страница 180: ...Chapter 7 Options 174 Type 2 Max 600 Watt Type 3 A ...