Chapter 6 - Parameter Description [I/O]
132
[Ssearch]
AXA-AXC is CLOSED during the inverter is speed
searching.
[Step pulse]
When Auto (Sequence) operation is selected in I/O-50,
AXA-AXC outputs pulse signals on every step.
[AXA-AXC configured as ‘Step pulse’]
[Seq pulse]
When Auto (Sequence) operation is selected in I/O-50,
AXA-AXC outputs pulse signals on the last step.
[AXA-AXC configured as ‘Step pulse’]
[Ready]
AXA-AXC is CLOSED when the inverter is ready to run.
[Trv. ACC]
CLOSED when output frequency reaches Accel
frequency.
[Trv. DEC]
CLOSED when output frequency reaches Decel
frequency.
[MMC]
Automatically set to ‘MMC’ when ‘MMC’ is selected in
APP-01.
[Zspd Dect]
0 rpm detection signal in Vector Control
[Torq Dect]
Torque detection signal in Vector and Sensorless Vector
Control.
Output Frequency
Time
Seq# / 2F
Seq# / 1F
Seq# / 3F
1T
1S
2T
2S
3T
3S
1D
(Forward)
2D
(Forward)
3D
(Reverse)
DRV-02
AXA-AXC
‘Step pulse’
Time
ON
Minimum 100msec
AXA-AXC
‘Step pulse’
P1-CM
‘SEQ-L’
ON
Output Frequency
Time
ON
Time
ON
Time
P2-CM
‘SEQ-M’
P3-CM
‘Go step’
ON
ON
ON
ON
SEQ1 / 2F
SEQ2 / 2F
SEQ1 / 1F
SEQ3 / 2F
SEQ3 / 1F
Sequence 1
Sequence 3
Sequence 2
ON
Time
ON
ON
ON
ON
Minimum 100msec
Time
Related Functions:
I/O-50 ~ I/O-84 [Auto Operation]