DMD660 - OPERATING MANUAL // PAGE 19
8 ASSEMBLY - THICK TUBE DOWN
This section describes assembly for the DMD660 into "Thick Tube Down" Height-Adjustable Columns. The
following assembly instructions are valid only for versions of the DMD660 with Drop&Drive. Consult the
accompanying Datasheet if you are unsure whether your version of the DMD660 features Drop&Drive.
If you are inserting the DMD660 into a “Thick Tube Up” Height-Adjustable Column, ignore this chapter and
return to Chapter 7. If you have already inserted the Actuator, proceed to Chapter 9.
8.1 REQUIRED COMPONENTS
1
DMD660 Actuator
2
Height-Adjustable Column
3
Middle Tube Adapter (mounted into the Height-Adjustable Column)
8.1.1 MIDDLE TUBE ADAPTER
The Middle Tube Adapter (Fig. 8) fixes the DMD660 to the Middle Tube of the Height-Adjustable Column. It
is supplied by the Reseller.
Fig. 8:
Example of a Middle Tube Adapter (Thick Tube Down)
The Middle Tube Adapter must be securely fixed into the Middle Tube of the Height-Adjustable Column
before the assembly process can begin.
NOTICE
LOGICDATA provides specifications for the Middle Tube Adapter only on request.
These include dimensions and tolerances, as well as notes on material selection and
assembly. Assembling the Middle Tube with an Adapter that has not been approved by
LOGICDATA may cause damage to the product. In this scenario, all warranty claims are
void.
NOTICE
To avoid damage to the system, measure the friction between the Tubes before connect-
ing the Actuator.
NOTICE
The maximum pull force on the Middle Tube Adapter may not exceed 150N. If this force
is exceeded, a functional reset cannot be guaranteed.