28
5 Curing
5.5 EMERGENCY Shutdown
The Emergency Stop switch must be activated in a case of emergency.
Cases are:
– Human life or health is in danger.
– There is a danger of overheating and burning of the adhesive or producing too much
vapors.
– There is a danger that the work piece or equipment will be damaged.
Press the emergency stop button:
– The bulb is powered off immediately.
– The solenoid valve for the shutter is released, the shutter closes.
– The door interlock is released.
☞
Note!
The +24 V control voltage and the Fan are not turned off!
Returning to Operation after an Emergency Stop
The unit does not automatically restart after an emergency stop.
The following steps have to be done:
WARNING!
Before releasing the emergency stop button, be sure that there is no longer an
emergency condition.
Clear fault.
Unlock emergency stop button.
Push Selector/Confirm button
3
to quit fault.
The system cools down the bulb until 100 % cooled.
After this, the normal operating menu is displayed again.
Ignite lamp as described in section 4.5 Start-up, or
Press power switch to switch the unit off.
5.6 Startup with Bulb in Cold Condition
See section 4.5
5.7 Startup with Bulb at Operating Temperature
Display indicates fault 10
Bulb does not ignite
Reset fault.
Allow bulb to cool down (approx. 5 minutes), then re-ignite.