4 Installation
4.8 Switch from 500 W to 1000 W
Turn 500 W / 1000 W selector switch to required position.
4.9 Resetting Bulb Operating Hours
Turn the button until the “
Operating
hours
” menu option is displayed.
Push button for 5 seconds to reset lamp
operating hours and lamp ignition count
to Zero. Also the numbers of ignitions
will be reset.
4.10 Calibration
For further information see section 2.1.
Turn the button until the “
UV Adjust.
”
Menu option is displayed.
Push the button to activate the UV
Adjustment setup option.
Adjust required value.
Push again to accept and store the
value.
4.11 Adjusting UV Minimum
For further information see section 2.1.
Turn the button until the “
UV Minimum
”
menu option is displayed.
Push the button to activate the UV
Minimum setup option.
Adjust required value.
Push again to accept and store the
value.