4 Installation
4.5 Start-up
Press power switch to switch the unit on.
As an example the chamber version
97055.
Follow instructions on the display to
ignite the bulb.
Push the button to ignite the lamp.
The warm-up phase takes about 80 s. No cure cycle can be started during warm-up.
Next, the following information is
displayed:
Start of bulb warm-up phase
(bulb cold); 0 s.
Mid-time of warm-up phase;
about 9 s passed;
status: Ignition has occurred.
Near end of warm-up phase;
about 65 s passed;
status: Ignition has occurred.
As soon as this information is displayed
after warm-up or at the end of a cure
cycle, the system is in ready state and the
lamp power is adjusted to 500 W.
The green LED lights up.
For 97056 or for 97055 fitted with a UV
sensor, the display indicates not only
exposure time but also the UV level
measured, displayed as % instead of
dashes. When UVALOC is started for the
first time, this value is 0% as no
measurement has yet been made.
The “close door” message is displayed
only for the chamber version in case the
door has not been closed.