Instructions
Saddle-mount unit GSG-S-VM
57 - 72
010710-03-EN BA GSG-S-VM / 13.07.2020
Lubrication points of telescopic guides:
•
Lubricate the telescopic guides
on the cross-flow fan tunnels
using long-lasting grease.
•
After lubrication extend and re-
tract the tunnel one time to dis-
tribute the grease evenly on
the guide tubes. (Fig. 37)
Fig. 37
Pump:
Oil tank
•
Check pump oil level.
Check oil in inspection glass reg-
ularly; in case of discoloration,
check membranes!
Fig. 38
•
First oil change of approx. 50 hours of operation, or at the end of
the season.
•
Further oil changes after every 500 hours of operation, or at the
end of the season.
•
Use SAE 20W 40 oil: quantity = 1.35 l
•
Check the membranes annually for damage; if they need to be
replaced, use only