In the event of excessive foaming, we recommend the use of an
anti-foaming agent in the spray liquid.
Use commercially available anti-foaming agents. Alternatively, it
is also possible to add 0.02 l of rapeseed oil or salad oil for each
1000 l of spray liquid.
Note:
It is important to set the recycling suction power to a value, that
the sump bottom is just slightly covered.
If e.g. the recycling regulator is closed too much (Fig. 22), then
the sump may overflow.
When using non-foaming agents, the recycling regulator may
stay open.
•
Note:
After end of spraying operation, shut-off the unit in following se-
quence:
1. Nozzles
2. Recycling
3. Pump
See also adequate information sticker on tank
Using this shut-off sequence avoids dripping of the agent after
end of operation.