Torchmate 2x2 Growth Series
76
Run and connect
the wires
Step D6b: Wiring for non-Lincoln Electric plasma cutters
Wiring for Lincoln Electric plasma cutters is simplified because all connections to the plasma cutter are con-
tained in the CNC cable. The additional wiring steps are based on the diagram on the following page.
• Run the torch and work leads from the table to the plasma power unit, then make the CNC
cable connections to the VFC and Accumove2.
• Connect the #12 (Red) and #14 (Black) for Arc Established [OK to Move] to the
Accumove Input cable.
• Connect the #3 (Green) and #4 (Black) wires to the #1 output terminals on the
Accumove2 [Start Arc (Now)]. Use the Terminal block and 22-guage wire (not supplied).
• Connect the (-)D and (+)G cables to the VFC black (-) and red (+) cables. Be sure to
observe the correct polarity on this [Raw Arc Voltage] signal.
• Refer to your plasma power unit manual for the location of the Raw Arc Voltage
signal.
• Contact
Torchmate Technical Support
for assistance with this step. Provide the
brand and model number of your plasma power unit and ask for instructions on
connecting your VFC to the Raw Arc Voltage. Call Monday through Friday
from 6 AM to 4 PM (06:00 to 16:00), Pacific Time Zone:
Toll Free: 1-866-571-1066, International: 775-673-2200,
Fax: 775-673-2206, Email:
• Run the height control cable from the VFC to the Accumove.the wiring components for
the control of the torch and control of the AVHC unit. Both ends of this cable are the
same. It’s best to position the VFC close to the plasma power unit and well away from
the Accumove2 in order to minimize EMI problems.
• Run the Ohmic cap cable from the torch lead the VFC using the orange wire.
• Optionally, run the wire from the magnetic breakaway sensor to the Accumove2.
Breakaway port.
Qty
Part
Description
Part #
1
Height Control VFC, ACCUMOVE
TMS-101-1100-01
1
Height Control Cable, ACCUMOVE
TMS-103-5000-01
1
Arc Voltage Ohmic Sense Cable, Height
Control
TMS-101-1109-01
1
Terminal Block Plug 2POS STR 5.08MM TMS-403-0076-01
1
Input Cable, ACCUMOVE, TORCHMATE
PRO
TMS-103-5000-03
Required parts /
components
Содержание Growth Series
Страница 11: ...Assembly Guide 1 Safety Information ...
Страница 21: ...Assembly Guide 11 Receiving and Preparation ...
Страница 33: ...Assembly Guide 23 Assembling the cutting table ...
Страница 43: ...Assembly Guide 33 Binding the Accumove 2 ...
Страница 56: ...Torchmate Growth Series 46 ...
Страница 57: ...Assembly Guide 47 Coupling the water table optional ...
Страница 69: ...Assembly Guide 59 Deploying the Plasma Cutter ...
Страница 88: ...Torchmate 2x2 Growth Series 78 ...
Страница 89: ...Assembly Guide 79 Maintenance and Parts ...