UMX-OPT-TX150R
User’s Manual
Section 10. Programmers reference
Page 75 / 107
10.4.8. Count HDCP keys
Description:
If there is an HDCP source on the HDMI input of the device, the device can
ask the source whether it can handle <num> piece of sink devices.
Format
Example
Command {:HDCPTEST<in>@<num>}
→ {:hdcptest4@9}
Response (HDCPTEST=<resp>)CrLf
← (HDCPTEST=SUCCESS)CrLf
Legend:
<in>
input port where the key counting will be executed. This input
port must be selected.
<num>
the number of the HDCP keys
<res>
Result of the HDCP key counting:
SUCCESS
: The source on the <in> input can handle <num>
HDCP sink devices.
FAIL
: The source on the <in> input cannot handle <num>
HDCP sink devices.
UNAVAILABLE
: If the <in>
input isn’t a HDCP compliant input
(e.g. VGA), the key counting function isn’t available.
NOAUTH
: If the <in> input is a HDCP compliant input but there
is no connected source, the device cannot execute the key
counting.
Explanation:
The source on the 4
th
input can handle 9 HDCP sink devices.
10.4.9. Restart transmitter
Description
: The extender can be restarted without unplugging power.
Format
Example
Command {RST}
→ {rst}
Response
(Booting…)CrLf
(<name>●READY!)CrLf
←
←
(Booting…)CrLf
(UMX-OPT-TX150R READY!)
Legend:
<name>
is the type of the extender
Explanation:
The extender reboots and sends a message when it is ready.
Info:
The response can be seen only if the connection to the extender via RS-232 is still alive.
The response cannot be seen and reconnect is always necessary in case of USB
connection.
10.4.10. View error list
Description
: Shows the basic error list since last boot up.
Format
Example
Command {ELIST=?}
→ {elist=?}
Response (ELIST#<num>
●<elevel>●<code>
●<param>●<occ>
)CrLf
…
(ELIST#<num>
●<elevel>●<code>
●<param>●<occ>
)CrLf
←
←
(ELIST#1 Notice BOOT
p:6 o:1
)
CrLf
…
(ELIST#2 Notice READY
p:0 o:1)
CrLf
Legend:
<num>:
line number
<elevel>:
NOTICE =
Not an error. Initialization information.
WARNING = Possible problem without influencing normal
operation.
MATTER =
Problem that may lead to further errors.
ERROR =
Serious error. Must report to support.
FATAL =
Fatal error. Normal operation is not possible.