7. LW2 Programmers’ Reference
MMX8x4-HT series – User's Manual
89
Applied firmware package: v1.2.2b5 | LDC software: v2.2.1
7.3.8.
View Installed Board(s)
Shows the hardware name and revision of the installed card.
Command and Response
{IS}
(SL#•0•
<MB_DESC>
)CrLf
(SL•END)CrLf
Example
{is}
(SL#0 Mmx8x4-Mb8)
(SL#1 MMX8X4-CONN Right)
(SL#2 MMX8X4-CONN Left)
(SL#3 MX-4TPS2-4HDMI-IB)
(SL#4 MX-HDMI-3D-STEREO-ADDON)
(SL#5 MX-HDMI-3D-STEREO-ADDON)
(SL#6 MX-4TPS2-4HDMI-OB)
(SL#7 MMX8X4-BASIC-MIC-ADDON)
(SL#8 DCM-G3)
(SL END)
The device reports its motherboard (slot 0).
7.3.9.
View Firmware for all Controllers’
Shows the firmware package versions of all installed controllers.
Command and Response
{FC}
(CF•<DESC>)CrLf
(CF•<DESC>)CrLf
…
(CF•END)CrLf
Parameters
<FW_VER>
is the firmware version. It is followed by
<s>
string which may indicate special versions.
Example
{fc}
(CF MMX8x4-HT420M 1.0.0b15 r17)
(SL END)
The device has one control panel.
#firmwareversion
7.3.10.
Restart the Matrix Router
The device can be restarted without unplugging power.
#reboot #restart
Command and Response
{RST}
Example
{rst}
The device reboots; no response is sent in this case.
7.3.11. Query Health Status
Internal voltages and measured temperature values are shown.
Command and Response
{ST}
(ST•
<DESC>
)CrLf
Example
{st}
(ST CPU 5.14V 3.38V 57.29C 63.30C 63.00C 51.05C 62.74C 63.25C 58.44C)
7.3.12.
Restore Factory Default Settings
Settings can be reset to factory default values as follows:
#factory
Command and Response
{FACTORY=ALL}
(FACTORY ALL…)CrLf
Example
{factory=all}
(FACTORY ALL…)
All settings and parameters are reset to factory default, see the table in the
section.