SYMPTOM
CAUSE
REMEDY
9. PLATFORM WILL NOT
LOWER
Obstruction in scissor
assembly or under platform.
Raise platform slightly and
remove obstruction.
WARNING: Do not work under platform without scissor
spreader in place.
"Lower" valve on main
manifold will not shift due to
dirt or defective seals.
Remove, clean valve with
solvent, replace seals if
necessary. Reassemble
and test. If problem
continues, consider other
causes or replace valve.
10. (Opt.)
TURBINE OIL
WILL NOT PUMP
Inline moisture filter has
reached its moisture limit.
Replace.
Valve on motor/pump will
not operate
Remove, clean valve with
solvent, replace seals if
necessary. Reassemble
and test. If problem
continues, consider other
causes or replace valve.