11. Test Run
47
MULTI V Water IV
Heat Pump
Installation of Outside Units
11.3 How to Cope with Abnormal Test Run
* When CH24 or CH180 error occurs during the test operation of the heater, the inside of the panel heat exchanger
may be partially frozen and therefore, be sure to get rid of its cause and then, re-operate the device.
(The root cause of partial freezing: The lack of flow of heat-sourced water, suspension of water, lack of cooling
medium, infiltration of foreign substance inside of panel heat exchanger )
Item
Phenomenon
Cause
Checkpoint and resolution
Whether
heat water
is supplied
CH24
When connecting the flow switch,
heat-sourced water doesn’t flow or the
amount of its flow lacks due to the checked
error related to heat-sourced water.
Check whether the heat source water supply pump is operating.
Check whether the heat source water supply pipe is clogged.
(Clean strainer, valve locked, valve issue, air trapped etc.)
Check whether the flow switch is normal condition.
(Flow switch problem, arbitrary control, disconnection etc.)
CH32
Heat water not supplied or flow rate is
insufficient
Check whether heat source water supply pump is operating.
Check whether the heat source water supply pipe is clogged.
(Clean strainer, valve locked, valve issue, air trapped etc.)
CH34
Heat water not supplied or flow rate is
insufficient (During cooling)
Check whether heat source water supply pump is operating.
Check whether the heat source water supply pipe is clogged.
(Clean strainer, valve locked, valve issue, air trapped etc.)
CH180
Heat water not supplied or flow rate is
insufficient (During heating)
Check whether heat source water supply pump is operating.
Check whether the heat source water supply pipe is clogged.
(Clean strainer, valve locked, valve issue, air trapped etc.)
Содержание MULTI V WATER IV ARWN080LAS4
Страница 1: ...Heat Pump 380 415V 380V R410A 50Hz 60Hz 0CVW0 01N Replaces 0CVT0 01M P No MFL61741615 ...
Страница 27: ...17 MULTI V Water IV Heat Pump Outside Units 4 Wiring Diagrams ARWN080LAS4 ARWN100LAS4 ARWN140LAS4 ...
Страница 28: ...MULTI V Water IV Heat Pump 4 Wiring Diagrams 18 Outside Units ARWN200LAS4 ...
Страница 392: ...Special Guide MULTI V Water IV Heat Pump 1 Cautions for Refrigerant Leaks ...