MULTI V Water IV
Heat Pump
Outside Units
8. Operation Limits
Note
These figures assume the following operating conditions:
Equivalent piping length:7.5m
Level difference:0m
Inlet water temperature (°C)
Indoor temperature (°CWB)
Cooling
15
10
10
15
20
25
30
35
45
40
20
25
30
Range for continuous operation
Range for
operation
Range for pull down operation
Inlet water temperature (°C)
Indoor temperature (°CDB)
Heating
10
15
20
25
30
-5
10
15
20
25
30
35
45
40
Range for
operation
Range for continuous operation
Range for warming up operation