-4-2-
COMPONENTS
TEST PROCEDURE
RESULTS
Oven Sensor
1. Refer to page 3-13 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Normal: Approximately
1.09 kΩ ± 10%
If not replace
Conv. heater
1. Remove wire leads
2. Measure resistance after cooling down
Normal : Approximately 27Ω
Abnomal : Infinite(opened)
Door switch
1. Refer to page 3-7 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Door open
Door closed
Continuity
Infinite
NOTE: Ω Value was tested at room temperature
(77F/25˚C)
NOTE: Ω Value was tested at room temperature
(77F/25˚C)