Programming Manual for Digital Key Telephone System
LDK-
300 & LDK-100
System Features
3-20
Self Diagnostic
Description
The user can receive the status indication of
system resource by e-mail.
When the SMDR is full, the user can receive the
warning indication by e-mail.
Operation
Operation of this feature is automatic when
programmed
Admin Programming
n
SMTP Mail Server IP Adderss (PGM 177)
n
SMTP User Mail Adderss (PGM 177)
n
SMTP Mail Send Weekly Set(PGM 177)
n
SMTP Mail Send Daily Set(PGM 177)
n
SMTP Mail Auto Send Set(PGM 177)
n
SMTP Mail Auto Delete Set(PGM 177)
Condition
1. The Mail Server should be existed.
SMDR
Description
Station Message Detail Recording (SMDR) will
provide details on both incoming and outgoing
calls.
Operation
To print SMDR,
1. Activate PC utility on PC.
2. Connect serial port of MFB to the serial port of
PC with the cable of RS-232C.
3. Press the
[TRANS/PGM]
button.
4. Dial
0111
(Station Base) or
0113
(Group
Base).
5. Enter the station or group range.
6. After finishing the call, the SMDR is printed to
PC.
To delete SMDR,
1. Press the [TRANS/PGM] button.
2. Dial
0112
(Station Base) or
0113
(Group
Base).
To abort SMDR printing,
1. Press the
[TRANS/PGM]
button.
2. Dial
0115
.
Admin Programming
n
SMDR Start Timer (PGM 177-BTN 13)
n
SMDR Attribute (PGM 177)
n
Metering Type (PGM 142-BTN 3)
n
SLT DTMF RLS Timer ( PGM 181 – BTN13)
Condition
1. There is an assignable database option; If
SMDR – Long Distance Only is selected, only
outgoing toll call will be printed and SMDR –
All Call/Long Distance Call Only is selected,
incoming and outgoing local and long
distance call are provided.
2. If user dials any number with a programmed
long distance code as the first and second
digit dialed or any number with more than
maximum local call digit count, it will be
regarded as long distance call. (Max. local call
digit count is programmable and the default
value is 7.)
3. The SMDR output records contain the
followings;
-
5-digit station call originator (terminating for
incoming) filed
-
3-digit used CO line field
-
8-digit call duration field (HH:MM:SS)
-
8-digit year, month, and day (YY/MM/DD)
-
5-digit time of day call originator field
-
1 digit call identification digit-first digit in digit
dial field
-
18-digit collected dial digit field
-
2-digit account group number field
-
5-digit pulse metering count field
-
10-digit call cost field
-
12-digit account code field
4. When the SMDR storage pools are almost
exhausted, the system gives “Buffer full”
warning signal to the attendant. And the LCD
of attendant station will indicate how many
SMDR records are remained to store for
some intervals.
5. Some stations may be grouped to count the
billing with a SMDR receipt using a SMDR
account group.