LIP-8002/8002A
iPECS
Installer
Guide
86
Section
Field Name
Description
de_register
Enables de-registration of each line during a reboot prior to
re-registering.
Valid values are enable or disable
Default is enable
line1_proxy_address
Assgin the proxy address for the SIP proxy server.
Valid value is an IP address or FQDN.
Default is blank.
line1_proxy_port
Assigns the port number for the SIP proxy server.
Valid values are 1024 to 32000.
The default is 5060.
line1_displayname
Specifies the caller identification for the line, the phone sends
the caller id for the line.
Valid value is up to 50 characters.
The default is blank.
line1_name
Defines the SIP user id that is often a number or SIP address
for use when registering. Enter a number without dashes,
enter 555-0100 as 5550100, or a SIP address without the
host name.
Valid value is up to 50 characters.
The default is blank.
line1_authname
Specifies the name for authentication if the proxy server
challenges the line registration. It is required only if a proxy
server requires authentication.
Valid value is up to 50 characters.
The default is blank.
line1_password
Specifies the password for authentication if the proxy server
challenges the line registration.
Valid value is up to 50 characters.
The default is blank.
line1_delayed_ring
Specifies a delay in the audible ring for the line. Delayed ring
is adjustable from 0 to 10 seconds in 1-second increments
Valid values are 0 to 10 seconds.
The default is 0.
handsfree
Specifies the gain level for the phone’s handsfree speaker.
Valid values are 1 through 11.
The default is 6.
handset
Specifies the gain level for the phone’s handset.
Valid values are 1 through 11.
The default is 6.
ring
Specifies the gain level for the phone’s ring.
Valid values are 1 through 11.
The default is 6.
lcd
Specifies the contrast level for the phone’s LCD.
Valid values are 1 through 7.
The default is 4.
ringer_off
Toggles the ringer on and off.
Valid values are 1 (on) and 0 (off).
The default is 1 (on).
DSP
VAD
Sets voice activation detection (VAD).
Valid values are 1 (on) and 0 (off).
The default is 0.