LIP-8002/8002A
iPECS
Installer
Guide
25
To assign an RTP Start Port:
Press the Settings (
) button. If the LCD Menu is locked, use the unlock procedure. Refer
to
section 3.3
.
Press the
digit, or move the cursor to
2.SIP Configuration
using the navigation buttons
and press the
OK
button.
Press the
digit, or move the cursor to
7.RTP Start Port
using the navigation buttons and
press the
OK
button.
Input the RTP Start Port using the dial pad and press the
OK
button to save your entry.
Move to another parameter with the navigation buttons and continue the session or press the
Settings (
) button to exit the configuration session.
Changing the RTP Start Port requires a reboot of the IP Phone; when you leave the
menu, you will receive a reboot notice. The IP Phone must reboot to utilize the new
values entered.
3.5.2.7 Proxy Registration
If Proxy Registration is set to Yes, the IP Phone will register with the appropriate call or proxy
server upon initial power-up, during a reboot and at periodic intervals based on the timer defined
in
section 3.5.2.8
.
To enable Proxy Registration:
Press the Settings (
) button. If the LCD Menu is locked, use the unlock procedure. Refer
to
section 3.3
.
Press the
digit, or move the cursor to
2.SIP Configuration
using the navigation buttons
and press the
OK
button.
Press the
button, or move the cursor to
8.Proxy Registration
using the navigation
buttons and press the
OK
button.
To change, select Yes or No using the
Up
/
Down
navigation buttons and press the
OK
button.
Move to another parameter with the navigation buttons and continue the session or press the
Settings (
) button to exit the configuration session.
Changing the Proxy Registration requires a reboot of the IP Phone; when you leave the
menu, you will receive a reboot notice. The IP Phone must reboot to utilize the new
values entered.
3.5.2.8 Register Expires
To assure a connection with the proxy or SIP call server, the IP Phone periodically re-registers.
Unless defined by the host server during registration, the Register Expires timer determines the
interval between registration attempts and is set from 0 to 6400 seconds, default 3600 seconds.
To modify the Register Expires timer:
Press the Settings (
) button. If the LCD Menu is locked, use the unlock procedure. Refer
to
section 3.3
.