C
HAPTER
4
| Making Network Connections
Twisted-Pair Devices
– 38 –
ES-2024G/2024GP
N
OTE
:
Avoid using flow control on a port connected to a hub unless it is
actually required to solve a problem. Otherwise back pressure jamming
signals may degrade overall performance for the segment connected to the
hub.
3.
As each connection is made, the Link LED (on the switch)
corresponding to each port will turn on (green or amber) to indicate
that the connection is valid.
N
ETWORK
W
IRING
C
ONNECTIONS
Today, the punch-down block is an integral part of many of the newer
equipment racks. Actually it is a part of the patch panel. Instructions for
making connections in the wiring closet with this type of equipment
follows.
1.
Attach one end of a patch cable to an available port on the switch, and
the other end to the patch panel.
2.
If not already in place, attach one end of a cable segment to the back
of the patch panel where the punch-down block is located, and the
other end to a modular wall outlet.
3.
Label the cables to simplify future troubleshooting. See